CM50MD-12H MITSUBISHI, CM50MD-12H Datasheet
CM50MD-12H
Available stocks
Related parts for CM50MD-12H
CM50MD-12H Summary of contents
Page 1
... 4.5 MOUNTING HOLES 12.5 12 12.5 12.5 5 105 ±0.25 115 LABEL MITSUBISHI IGBT MODULES CM50MD-12H MEDIUM POWER SWITCHING USE ¡I C ..................................................................... ¡V CES ............................................................ ¡Insulated Type ¡CIB Module 3 Inverter+3 Converter+Brake ¡UL Recognized R5 0.6 MAIN CIRCUIT TERMINAL INSULATED TYPE 50A 600V Yellow Card No. E80276 (N) File No ...
Page 2
... AC 1 min. iso — Mounting torque Mounting M4 screw — Weight Typical value MEDIUM POWER SWITCHING USE Condition = 25 C (Note (Note Condition = 25 C (Note Condition Condition MITSUBISHI IGBT MODULES CM50MD-12H INSULATED TYPE Rating Unit 600 100 100 A 104 W Rating Unit 600 V 20 ...
Page 3
... 150 C = 10V = 0V = 300V 50A 15V 50A, Clamp diode part Condition = 150 C RRM j = 50A ) does not exceed T j MITSUBISHI IGBT MODULES CM50MD-12H INSULATED TYPE Limits Unit Min. Typ. Max. — — 4.5 6 7.5 V — — 0.5 A — 2.2 2.8 V — ...
Page 4
... TRANSFER CHARACTERISTICS 100 V = 10V (V) GATE-EMITTER VOLTAGE V CE COLLECTOR-EMITTER SATURATION VOLTAGE CHARACTERISTICS 100 (A) GATE-EMITTER VOLTAGE V C CAPACITANCE VS –1 10 3.2 4 (V) COLLECTOR-EMITTER VOLTAGE V EC MITSUBISHI IGBT MODULES CM50MD-12H INSULATED TYPE (TYPICAL 125 (V) GE (TYPICAL 100A 50A 20A ( (TYPICAL ies C oes C res (V) CE Feb.1999 ...
Page 5
... T = 25° EMITTER CURRENT I TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (FWDi part) –3 –2 – Single Pulse 25° 1.9°C/ W th(j – –1 – –2 – –3 10 –3 – TIME (s) CM50MD-12H INSULATED TYPE – ( – – –3 10 –4 – Feb.1999 ...