HM1-65162/883 Intersil Corporation, HM1-65162/883 Datasheet
HM1-65162/883
Available stocks
Related parts for HM1-65162/883
HM1-65162/883 Summary of contents
Page 1
... No Clocks or Strobes Required • Wide Temperature Range . . . . . . . . . . -55 • Equal Cycle and Access Time • Single 5V Supply • Gated Inputs - No Pull-Up or Pull-Down Resistors Required Ordering Information 70ns/20µA 90ns/40µA HM1-65162B/883 HM1-65162/883 HM4-65162B/883 HM4-65162/883 Pinouts HM-65162/883 (CERDIP) TOP VIEW VCC ...
Page 2
Functional Diagram ROW A4 ADDRESS A5 BUFFER HM-65162/883 128 X 128 ROW MEMORY ARRAY DECODER 128 128 COLUMN DECODER AND DATA INPUT / OUTPUT (X8 ...
Page 3
Absolute Maximum Ratings Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 4
TABLE 2. HM-65162/883 AC ELECTRICAL PERFORMANCE SPECIFICATIONS Device Guaranteed and 100% Tested. (NOTES 1, 2) PARAMETER SYMBOL CONDITIONS Read/Write/ (1) TAVAX VCC = 4.5V Cycle Time and 5.5V Address (2) TAVQV VCC = 4.5V Access Time and 5.5V Chip Enable ...
Page 5
TABLE 3. HM-65162/883 ELECTRICAL PERFORMANCE SPECIFICATIONS, AC AND DC PARAMETER SYMBOL CONDITIONS Input CIN VCC = Open, Capacitance F = 1MHz, All Measurements Referenced To Device Ground I/O CI/O VCC = Open, Capacitance F = 1MHz, All Measurements Referenced To ...
Page 6
Timing Waveforms ADDRESS G (6) TGLQX E Q NOTE High for a Read Cycle. Addresses must remain stable for the duration of the read cycle. To read, G and E must be ≤ VIL and W ≥ ...
Page 7
Timing Waveforms (Continued) ADDRESS this write cycle G has control of the output after a period, TGHQZ. G switching the output to a high impedance state allows data applied without bus ...
Page 8
Test Circuit DUT (NOTE 1) C NOTE: 1. Test head capacitance includes stray and jig capacitance. Burn-In Circuits HM-65162/883 CERDIP TOP VIEW A7 24 F10 ...
Page 9
... Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use ...