PM20CTM060-3 MITSUBISHI, PM20CTM060-3 Datasheet
![no-image](/images/manufacturer_photos/0/4/451/mitsubishi_sml.jpg)
PM20CTM060-3
Available stocks
Related parts for PM20CTM060-3
PM20CTM060-3 Summary of contents
Page 1
... Tab #250 0.8 A LABEL MITSUBISHI INTELLIGENT POWER MODULES PM20CTM060-3 ¡600V, 20A Current-sense 6kHz IGBT type inverter ¡Built in IGBT gate drive circuit ¡Built in Faule OC, SC, OT & UV protection Fault output ¡1.5kW class inverter application ¡UL Recognized Yellow Card No. E80276 (N) A · B: TERMINAL NAME 1 ...
Page 2
... WPC N1 NC Applied between : UPC P VPC · Applied between : Sink current of F terminal O PM20CTM060-3 FLAT-BASE TYPE INSULATED PACKAGE WP1 VPC P VP1 UPC P UP1 GND In V GND ...
Page 3
... Trip level Temperature detection 15V Reset level D Trip level – 125 C (only N side) j Reset level V = 15V 15V 15V D PM20CTM060-3 FLAT-BASE TYPE INSULATED PACKAGE Ratings 400 450 500 –20 ~ +100 –40 ~ +125 2500 Limits Min. Typ. Max. — 1.8 2 — ...
Page 4
... N1- NC Applied between : Using application circuit Opto-coupler’s input signal Using application circuit Opto-coupler’s input signal 2V P-P PM20CTM060-3 FLAT-BASE TYPE INSULATED PACKAGE Limits Unit Min. Tye. Max. — — 2 — — 4 — — ...
Page 5
... REVERSE RECOVERY CHARACTERISTICS – –2 10 1.5 2.0 2.5 10 (V) COLLECTOR REVERSE CURRENT EC PM20CTM060-3 FLAT-BASE TYPE INSULATED PACKAGE COLLECTOR-EMITTER SATURATION VOLTAGE CHARACTERISTICS (TYPICAL 15V 10mA CIN 125 COLLECTOR CURRENT I (A) C SWITCHING TIME VS ...
Page 6
... Single Pulse 4 th(j – c – – – –3 – PM20CTM060-3 FLAT-BASE TYPE INSULATED PACKAGE – TIME (s) Aug.1999 ...