AIF04ZPFC-01NNTL Astec Power, AIF04ZPFC-01NNTL Datasheet - Page 20

no-image

AIF04ZPFC-01NNTL

Manufacturer Part Number
AIF04ZPFC-01NNTL
Description
Manufacturer
Astec Power
Datasheet
Technical Reference Note
AIF - PFC Power Factor
Correction Series
For example:
A PFC module driving 3 AIF80A300 400W modules @ 5V. Efficiency of the AIF80A300 module is 88%, the minimum
input voltage is 250V, the output voltage of the PFC is 380V, the required hold-up time is 20mS and the peak-to-peak
voltage V
is chosen to be 16V.
ripple
= 2 x (3 x 400/0.88) x 0.02 = 390µF (470 µF r20%)
C
O min
[(380-16)
2
-250
2
]
This figure is the minimum capacitance. To allow for capacitor tolerances and aging effects the actual value should
generally be around 1.5 times greater.
PF & Load Enable Connections and Timing
The PFC module must be supplied with a PF ENABLE signal to initiate the start-up sequence. The output of the LD
ENABLE pin goes HIGH (ON) once the PFC has completed the start-up sequence.
It is recommended that the LD ENABLE signals is always used to enable the load, however, if the load is to be enabled