NE555 Unisonic Technologies, NE555 Datasheet
NE555
Available stocks
Related parts for NE555
NE555 Summary of contents
Page 1
... UNISONIC TECHNOLOGIES CO., LTD NE555 SINGLE TIMER DESCRIPTION The UTC NE555 is a highly stable timer integrated circuit. It can be operated in both Astable and Monostable mode. With monostable operation, the time delay is precisely controlled by one external and one capacitor. With a stable operation as an oscillator the frequency and duty cycle are both accurately controlled with two external resistors and one capacitor ...
Page 2
... NE555 PIN CONFIGURATION UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw LINEAR INTEGRATED CIRCUIT QW-R106-001 ...
Page 3
... NE555 BLOCK DIAGRAM UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw LINEAR INTEGRATED CIRCUIT QW-R106-001 ...
Page 4
... NE555 ABSOLUTE MAXIMUM RATINGS PARAMETER Supply Voltage Power Dissipation Junction Temperature Operating Temperature Storage Temperature Note: Absolute maximum ratings are those values beyond which the device could be permanently damaged. Absolute maximum ratings are stress ratings only and functional device operation is not implied. ...
Page 5
... NE555 TYPICAL APPLICATION CIRCUIT C1 Trigger Lower comparator 1 R3 GND UTC NE555 UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw R Threshold Upper comparator R2 R1 FLIP-FLOP 3 LINEAR INTEGRATED CIRCUIT Discharge Reset QW-R106-001 ...
Page 6
... D. UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com. and dischages through R only. In the internal circuit of UTC NE555 , one and R , output is high and when C1 discharge through and the discharge time (output is low 0 T1=0.693*(R T2=0.693*R LINEAR INTEGRATED CIRCUIT ( Pin 8 ) ...
Page 7
... NE555 TYPICAL CHARACTERISTICS Low-Level Output Voltage vs Low-Level Output Current = =-55℃ 0.7 T =25℃ A 0.4 0.2 0.1 0.07 0.04 0.02 0. Low-Level Output Current,I Low-Level Output Voltage vs Low-Level Output Current =15V 0.7 0.4 T =25℃ A 0.2 T =125℃ A 0.1 0.07 0.04 0.02 0. Low-Level Output Current,I UNISONIC TECHNOLOGIES CO ...
Page 8
... NE555 UTC assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other parameters) listed in products specifications of any and all UTC products described or contained herein. UTC products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury ...