AT89C51CC02 Atmel Corporation, AT89C51CC02 Datasheet - Page 9

no-image

AT89C51CC02

Manufacturer Part Number
AT89C51CC02
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of AT89C51CC02

Flash (kbytes)
16 Kbytes
Max. Operating Frequency
40 MHz
Cpu
8051-12C
Max I/o Pins
20
Uart
1
Can
1
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
62.5
Sram (kbytes)
0.5
Eeprom (bytes)
2048
Self Program Memory
API
Operating Voltage (vcc)
3.0 to 5.5
Timers
4
Isp
UART/CAN
Watchdog
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89C51CC02CA-RATUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51CC02CA-SISUM
Manufacturer:
Atmel
Quantity:
972
Part Number:
AT89C51CC02CA-SISUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51CC02CA-SISUM
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT89C51CC02CA-TISUM
Manufacturer:
Atmel
Quantity:
1 492
Part Number:
AT89C51CC02CA-UM
Manufacturer:
AD
Quantity:
10
Part Number:
AT89C51CC02UA-RATUM
Manufacturer:
Atmel
Quantity:
1 845
Part Number:
AT89C51CC02UA-RATUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51CC02UA-SISUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51CC02UA-UM
Manufacturer:
NEDI
Quantity:
4
CAN Autobaud
CAN Autobaud
Limitation
Protocol
Generic CAN Frame
Description
Command Description
4208D–CAN–03/08
The following table shows the autobaud performance for a point-to-point connection in X1 mode.
Note:
The CAN Autobaud implemented in the bootloader is efficient only in point-to-point connection.
Because in a point-to-point connection, the transmit CAN message is repeated until a hardware
acknowledge is done by the receiver.
The bootloader can acknowledge an incoming CAN frame only if a configuration is found.
This functionality is not guaranteed on a network with several CAN nodes.
The CAN Protocol manages directly using hardware a checksum and an acknowledge.
Note:
This protocol allows to:
Overview of the protocol is detailed in Appendix-A.
Several CAN message identifiers are defined to manage this protocol.
Identifier: Identifies the frame (or message). Only the standard mode (11-bit) is used.
Control: Contains the DLC information (number of data in Data field) 4-bit.
Data: The data field consists of zero to eight bytes. The interpretation within the frame
depends on the Identifier field.
Initialize the communication
Program the Flash or EEPROM Data
Read the Flash or EEPROM Data
Program Configuration Information
Read Configuration and Manufacturer Information
Erase the Flash
Start the application
Identifier
ID_SELECT_NODE
100K
125K
250K
500K
20K
1M
1. ‘–’ Indicates impossible configuration.
To describe the ISP CAN Protocol, we use Symbolic name for Identifier, but default values are
given.
Identifier
8 MHz
11-bit
11.059
MHz
12 MHz 16 MHz 20 MHz
Command Effect
Open/Close a communication with a node
T89C51CC02 CAN Bootloader
Control
1 byte
22.1184
MHz
24 MHz 25 MHz 32 MHz 40 MHz
8 bytes max
Data
[CRIS]0h
Value
9