AD538BD Analog Devices Inc, AD538BD Datasheet - Page 3

IC MULT/DIV REALTIME ACU 18-CDIP

AD538BD

Manufacturer Part Number
AD538BD
Description
IC MULT/DIV REALTIME ACU 18-CDIP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD538BD

Rohs Status
RoHS non-compliant
Function
Analog Computational Unit
Number Of Bits/stages
1
Package / Case
18-CDIP (0.300", 7.62mm)
No. Of Multipliers / Dividers
1
No. Of Amplifiers
5
Supply Voltage Range
± 4.5V To ± 18V
Slew Rate
1.4V/µs
Operating Temperature Range
-25°C To +85°C
Digital Ic Case Style
DIP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD538BD
Manufacturer:
AD
Quantity:
900
Part Number:
AD538BD
Manufacturer:
ADI
Quantity:
613
Part Number:
AD538BD
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD538BD/883B
Manufacturer:
AD
Quantity:
900
Part Number:
AD538BDZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
RE-EXAMINATION OF MULTIPLIER/DIVIDER
ACCURACY
Traditionally, the “accuracy” (actually the errors) of analog
multipliers and dividers have been specified in terms of percent
of full scale. Thus specified, a 1% multiplier error with a 10 V
full-scale output would mean a worst case error of +100 mV at
“any” level within its designated output range. While this type
of error specification is easy to test evaluate, and interpret, it can
leave the user guessing as to how useful the multiplier actually is
at low output levels, those approaching the specified error limit
(in this case) 100 mV.
The AD538’s error sources do not follow the percent of full-
scale approach to specification, thus it more optimally fits the
needs of the very wide dynamic range applications for which it is
best suited. Rather than as a percent of full scale, the AD538’s
error as a multiplier or divider for a 100:1 (100 mV to 10 V)
input range is specified as the sum of two error components: a
percent of reading (ideal output) term plus a fixed output offset.
Following this format the AD538AD, operating as a multiplier
Total Error =
Total Error =
± Output V
± Input V
REV. D
REV. C
± Output V
(V
DYNAMIC
Y
+ V
RANGE
RANGE
INPUT
± % rdg
± % rdg
WIDE
100:1
Z
)/V
OS
OS
OS
×
X
V
Input
(in V)
10
10
1
0.1
1
10
5
10
Y
V
Input
(in V)
10
1
0.1
0.10
0.01
0.01
0.1
0.05
Z
Input
0.01
V
(in V)
10
0.1
1
0.1
2
0.01
0.1
X
Table I. Sample Error Calculation Chart (Worst Case)
Ideal
Output
(in V)
10
10
1
0.1
10
0.25
5
1
Total Offset
Error Term
(in mV)
0.5
0.25
0.5
0.25
0.5
0.25
0.5
0.25
28
16.75 (BD)
1.76
1
125.75 (AD)
75.4
25.53 (AD)
15.27 (BD)
(AD)
(BD)
(AD)
(BD)
(AD)
(BD)
(AD)
(BD)
(AD)
(AD)
(BD)
(BD)
–3–
or divider with inputs down to 100 mV, has a maximum error of
± 1% of reading ± 500 μV. Some sample total error calculations
for both grades over the 100:1 input range are illustrated in the
chart below. This error specification format is a familiar one to
designers and users of digital voltmeters where error is specified
as a percent of reading ± a certain number of digits on the meter
readout.
For operation as a multiplier or divider over a wider dynamic
range (>100:1), the AD538 has a more detailed error specifica-
tion that is the sum of three components: a percent of reading
term, an output offset term and an input offset term for the
V
tion, taken from Table I, for the AD538AD with V
100 mV and V
± 2.0% of reading ± 500 μV ± (1 V + 100 mV)/10 mV × 250 μV
or ± 2.0% of reading ±500 μV ± 27.5 mV. This example illus-
trates that with very low level inputs the AD538’s incremental
gain (V
bution to error substantial.
Y
/V
% of Reading
Error Term
(in mV)
100 (AD)
50 (BD)
100 (AD)
50 (BD)
10 (AD)
5
1
0.5 (BD)
200 (AD)
100 (BD)
5
2.5 (BD)
100 (AD)
50 (BD)
20 (AD)
10 (BD)
X
log ratio section. A sample application of this specifica-
Y
+ V
(BD)
(AD)
(AD)
Z
)/V
X
X
= 10 mV would yield a maximum error of
has increased to make the input offset contri-
Total Error
Summation
(in mV)
100.5 (AD)
50.25 (BD)
100.5 (AD)
50.25 (BD)
10.5
5.25
1.5
0.75
228
116.75 (BD)
6.76
3.5
225.75 (AD)
125.4 (BD)
45.53 (AD)
25.27 (BD)
(AD)
(BD)
(AD)
(BD)
(AD)
(AD)
(BD)
Total Error Summation
as a % of the Ideal
Output
1.0 (AD)
0.5 (BD)
1.0 (AD)
0.5 (BD)
1.05 (AD)
0.5 (BD)
1.5 (AD)
0.75 (BD)
2.28 (AD)
1.17 (BD)
2.7 (AD)
1.4 (BD)
4.52 (AD)
2.51 (BD)
4.55 (AD)
2.53 (BD)
AD538
Y
= 1 V, V
Z
=

Related parts for AD538BD