176392-4 TE Connectivity, 176392-4 Datasheet - Page 5

176392-4

Manufacturer Part Number
176392-4
Description
Manufacturer
TE Connectivity
Datasheets

Specifications of 176392-4

Product Type
Connector
Connector Type
Connector Assembly
Termination Method To Wire/cable
IDC
Sealed
No
Contact - Rated Current (a)
3
Operating Voltage Reference
AC/DC, AC, DC
Operating Voltage (vac)
125
Operating Voltage (vdc)
125
Wire/cable Size (awg)
26 – 28
Profile Height (y-axis) (mm [in])
5.10 [0.200]
Number Of Positions
4
Number Of Rows
1
Centerline (mm [in])
2.00 [0.079]
Mating Retention
Without
Length (x-axis) (mm [in])
10.00 [0.393]
Width (z-axis) (mm [in])
4.60 [0.181]
Contact Type
Socket
Contact Plating, Mating Area, Material
Gold
Contact Plating, Mating Area, Thickness (µm [?in])
0.2 [7.87]
Connector Style
Receptacle
Housing Color
Natural
Ul Flammability Rating
UL 94V-0
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Operating Temperature (°c [°f])
-30 – +105 [-22 – +221]
Applies To
Wire/Cable
Accepts Wire Insulation Diameter, Range (mm [in])
0.83 – 1.05 [0.032 – 0.041]
Application Use
Wire-to-Board, Wire-to-Board / Wire-to-Wire, Wire-to-Wire
Contact Transmits (typical Application)
Signal (Data)
Packaging Method
Bag, Box
ASHL-0005- ES REV B
3.8.1 (2)
3.8.1 (3)
3.8.1 (4)
Para.
Contact
Unmating Force
Tensile Strength
of Wire
Termination
Post Contact
Retention Force
Test Items
AMP Shanghai Ltd.
Tyco Electronics
14.7N Min. per contact.
0.784N Min.
# 26 (except UL
10272) & #24
Apply Ribbon Cables and Flat Shielded Wire
# 26 & #24
Wire Size
# 26 (UL
Wire Size
(AWG)
10272)
(AWG)
# 28
# 28
Requirements
Fig. 2 (To be continued)
Direction
Traverse
Direction
Traverse
Unit: N
Unit: N
[Min.]
[Min.]
5 of 12
11.8
11.8
14.7
PAGE
7.8
7.8
Direction
Direction
Document No.
Unit: N
Unit: N
[Min.]
[Min.]
Axial
Axial
14.7
19.6
14.7
19.6
19.6
108-5218
After preconditioning by using
applicable post for 3 cycles,
measure the force required to
unmate post by operating the
head at a rate of 50mm a
minute.
Apply a pull-off load to
terminated wire of contact
secured on the tester, at a rate
of 100mm a minute.
The load is applied in the axial
and lateral directions as
specified.
Apply axial load to contact by
operating at a rate of 50 mm a
minute, after preconditioning
for 3 insertion/extraction cycles
by using applicable post
contact. See Fig. 5.
Procedures
REV
S
LOC
ES