1375192-6 TE Connectivity, 1375192-6 Datasheet - Page 3

1375192-6

Manufacturer Part Number
1375192-6
Description
Manufacturer
TE Connectivity
Series
SL Seriesr
Datasheets

Specifications of 1375192-6

Product Type
Connector - Modular
Jack Type
RJ11 / RJ14 / RJ25
Wiring Pattern
USOC
Termination Style
110 Style Punch-Down
Keyed
No
Performance Category
Cat 3
Shielded
No
Number Of Positions
6
Netconnect Select System
No
Conductor O.d. (mm [in])
1.45 [0.057]
Mount Type
Panel Mount
Wire Range (solid) (mm [awg])
22-24
Wire Range (stranded) (mm² [awg])
24-26
110 Block Material
Polycarbonate
Contact Base Material
Phosphor Bronze
Contact Plating, Mating Area, Material
Gold
Contact Plating, Mating Area, Thickness (µm [?in])
1.27 [50]
Housing Color
Blue
Housing Material
Polycarbonate
Ul Flammability Rating
UL 94V-0
Dust Cover
Without
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Converted to comply with RoHS directive
Packaging Method
Poly Bag
Packaging Quantity
1
Voltage proof.
Vibration, jack-plug interface and
IDC-wire interface.
Mechanical shock, jack-plug
interface.
Durability, jack-plug interface using
a 6 position plug.
Durability, jack-plug interface.
Plug insertion force, jack-plug
interface.
Plug withdrawal force, jack-plug
interface.
Plug retention in jack, jack-plug
interface.
Rev K
Test Description
One m inute hold with no breakdown
or flashover.
No discontinuities of 1 m icrosecond
m axim um .
Shall rem ain m ated and show no
evidence of physical dam age.
See Note.
No discontinuities of 5
m icroseconds m axim um .
See Note.
Perm anent deflection of contacts in
positions 1 and 8 are acceptable if
the specim ens m eet the
requirem ents of additional tests.
See Note.
See Note.
5 pounds m axim um , unshielded.
8 pounds m axim um , shielded.
5 pounds m axim um , unshielded.
8 pounds m axim um , shielded.
Plug shall not dislodge from jack.
Figure 1 (continued)
MECHANICAL
Requirem ent
IEC 60512-4-1.
1000 volts AC at sea level.
Test between adjacent contacts of
m ated plug and jack.
IEC 60512-6-4.
Subject m ated plug and term inated
jack to frequency range of 10 to 55
Hz with displacem ent am plitude of
.014 inch. Sweep cycles per
direction shall be 5 in each direction
of 3 axis which are m utually
perpendicular planes.
IEC 60512-6-3.
Subject m ated plug and term inated
jack to 30 G's half-sine shock wave
of 11 m illiseconds duration. Three
shocks in each direction (2 total)
applied along 3 m utually
perpendicular planes (3 axis), 18
total shocks.
IEC 60512-9-1.
Mate and unm ate plug and jack
interface with latch inoperative for
200 cycles with a 6 position plug at
a m axim um rate of 500 (autom atic)
or 300 (m anual) cycles per hour.
IEC 60512-9-1.
Mate and unm ate plug and jack
interface with latch inoperative for
750 cycles at a m axim um rate of
500 (autom atic) or 300 (m anual)
cycles per hour.
IEC 60512-13-1.
Measure force required to m ate
plug and jack with latch depressed
at a m axim um rate of .5 inch per
m inute.
IEC 60512-13-1.
Measure force required to unm ate
plug and jack with latch depressed
at a m axim um rate of .5 inch per
m inute.
EIA 364-98.
Apply an axial load of 20 pounds to
plug housing at a rate of .5 inch per
m inute with plug m ated in jack and
latch engaged. Maintain load for 5
seconds.
Procedure
108-1990
3 of 8

Related parts for 1375192-6