2
2.1
2.1.1
6/11
Alternating current line switch - basic application
The ACS102-6T switch is triggered by a negative gate current flowing from the gate pin G.
The switch can be driven directly by the digital controller through a resistor as shown in
Figure
Thanks to its overvoltage protection and turn-off commutation performance, the ACS102-6T
switch can drive a small power, high-inductive load with neither varistor nor additional turn-
off snubber.
Figure 14. Typical application program
Protection against overvoltage: the best choice is ACS
In comparison with standard TRIACs, which are not robust against surge voltage, the
ACS102-6T is overvoltage self-protected, specified by the new parameter V
is useful in two operating conditions: in case of turn-off of very inductive load, and in case of
surge voltage that can occur on the electrical network.
High inductive load switch-off: turn-off overvoltage clamping
With high inductive and low rms current loads the rate of decrease of the current is very low.
An overvoltage can occur when the gate current is removed and the OUT current is lower
than I
As shown in
current decreases (1). The load current reaches the holding current level I
ACS turns off (3). The water valve, as an inductive load (up to 15 H), reacts as a current
generator and an overvoltage is created, which is clamped by the ACS (4). The current flows
through the ACS avalanche and decreases linearly to zero. During this time, the voltage
across the switch is limited to the clamping voltage V
of the load is dissipated in the clamping section that is designed for this purpose. When the
energy has been dissipated, the ACS voltage falls back to the mains voltage value (5).
H
14.
.
Power supply
Figure 15
and
Figure
Doc ID 11961 Rev 3
MCU
V
V
16, at the end of the last conduction half cycle, the load
dd
ss
Rg
CL
. The energy stored in the inductance
Valve
ACS102-6T
AC Mains
H
CL
(2), and the
. This feature