BTM 7742G Infineon Technologies, BTM 7742G Datasheet - Page 19

no-image

BTM 7742G

Manufacturer Part Number
BTM 7742G
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of BTM 7742G

Packages
PG-DSO-36
Operating Range
5.5 - 28.0 V
Rds (on) (typ)
250.0 mOhm
Id(lim)
12.0 A
Iq (typ)
5.0 µA
Diagnosis
OV, OT, OC-failure flag, current sense
6.4.4
Device State
1) Previous current sense assignment to be reset by IN1=IN2=low and both high side switches off (see
2) When both high side switches are in on state, the CS provides the sense signal for the high side switch, which has been
3) In short circuit of HSS or LSS, the junction temperature will arise and as soon as the over temperature shut down threshold
Data Sheet
Normal operation
Open-Load detection
mode
Over-voltage (OV)
Under-voltage (UV)
Overtemperature or
short circuit of HSS or
LSS
Current limitation
mode half bridge 1
Current limitation
mode half bridge 2
Inputs:
0 = Logic LOW
1 = Logic HIGH
X = 0 or 1
turned on first.
is reached the device will shut down and latch the status. Short circuit of HSS and LSS itself won’t be detected as failure.
3)
Tru
th Table
Inputs
INH
0
1
1
1
1
0
0
0
X
X
0
1
X
X
1
1
0
1
1
0
Switches
OFF = switched off
ON = switched on
X = switched on or off
IN1
0
0
0
1
1
0
1
1
X
X
0
X
1
X
0
1
1
X
X
X
IN2
0
0
1
0
1
1
0
1
X
X
0
X
X
1
X
X
X
0
1
1
Outputs
HS1 LS1 HS2 LS2 IS
OFF OFF OFF OFF 0
OFF ON
OFF ON
ON
ON
OFF OFF ON
ON
ON
ON
OFF OFF OFF OFF 0
OFF OFF OFF OFF 0
OFF OFF OFF OFF 1
ON
OFF ON
OFF OFF X
X
X
X
OFF OFF ON
OFF ON
OFF OFF OFF CS HS1
OFF ON
OFF ON
OFF X
X
X
X
19
OFF ON
ON
X
ON
OFF ON
OFF OFF 1
OFF CS HS2
OFF
OFF CS HS2
OFF CS
OFF 1
X
X
X
OFF 1
Status Flag IS:
CS = Current sense mode
1 = Logic HIGH (error)
0
CS HS1
CS
1
1
1
1
Block Description and Characteristics
2)
2)
1)
1)
1)
1)
Mode
Stand-by mode, reset
Enable Open-load detection
Enable Open-load detection
Shut-down of LSS,
HSS activated, error detected
UV lockout, reset
Stand-by mode, reset of latch
Shut-down with latch, error
detected
Short Circuit in LS1 detected,
half bridge 2 operates in normal
mode
Short Circuit in HS1 detected,
half bridge 2 operates in normal
mode
Short Circuit in HS1 detected
Short Circuit in LS2 detected,
half bridge 1 operates in normal
mode
Short Circuit in HS2 detected,
half bridge 1 operates in normal
mode
Short Circuit in HS2 detected
High Current H-Bridge
Rev. 1.0, 2010-05-28
Chapter
BTM7742G
6.4.3)