ITS 436L2S Infineon Technologies, ITS 436L2S Datasheet
ITS 436L2S
Specifications of ITS 436L2S
Related parts for ITS 436L2S
ITS 436L2S Summary of contents
Page 1
... Reverse battery protection with external resistor Loss of ground and loss of V Electrostatic discharge protection (ESD) Diagnostic Function Diagnostic feedback with open drain output Open load detection in ON-state Feedback of thermal shutdown in ON-state Infineon Technologies AG Package 38m 4.75...41V 9.8A 40A -30 …+85°C protection ...
Page 2
... Positive power supply voltage The tab is shorted to pin Diagnostic feedback, low on failure 5 OUT Positive power supply voltage Tab V bb The tab is shorted to pin 3 Infineon Technologies AG gate current limit control + charge clamp for logic pump inductive load temperature sensor Open load ...
Page 3
... DUT connected to the generator per ISO 7637-1 and DIN 40839 Load dump the maximum inductive switch-off energy Device on 50mm*50mm*1.5mm epoxy PCB FR4 with 6cm connection. PCB is vertical without blown air. Infineon Technologies °C unless otherwise specified 13 °C ...
Page 4
... Supply voltages higher than V resistor for the GND connection is recommended. See also V circuit diagram page Measured with load 9 ) Add > 0, add Infineon Technologies AG Symbol R T =25 ° =150 ° L(ISO) I L(GNDhigh 90% V ...
Page 5
... Input and Status currents have to be limited (see max. ratings page 3 and circuit page 7 not subject to production test, specified by design ground resistor R is used, add the voltage drop across this resistor. GND Infineon Technologies AG Symbol I L(lim) T =-40° =25° =+150° ...
Page 6
... H H Overtem perature "Low" Level X = don't care H = "High" Level Status signal after the time delay shown in the diagrams (see fig 5. page 11) Infineon Technologies AG Status BTS 436L2 high impedance, potential depends on external circuit Page 6 PROFET ® ITS436L2 ...
Page 7
... ESD-Zener diode: 6.1 V typ., max 5.0 mA 1.6 mA. The use of ESD zener diodes as voltage clamp at DC conditions is not recommended. Inductive and overvoltage output clamp V Z GND V clamped typ. ON Infineon Technologies AG Overvolt. and reverse batt. protection OUT OUT V = 6.1 V typ., V ...
Page 8
... Consider at your PCB layout that in the case of Vbb dis- connection with energized inductive load all the load current flows through the GND connection. Infineon Technologies AG Inductive Load switch-off energy dissipation OUT 5 ...
Page 9
... Typ. standby current 9...34 V, IN1,2 = low bb(off bb(off - Infineon Technologies 150°C 25°C -40° [V] bb 100 150 200 T [°C] j Page 9 PROFET ® ITS436L2 2006-Mar-28 ...
Page 10
... Figure 2a: Switching a resistive load, turn-on/off time and slew rate definition OUT 90 dV/dton 10 Infineon Technologies AG Figure 2b: Switching a lamp OUT The initial peak current should be limited by the lamp and not by the current limit of the device. Figure 2c: Switching an inductive load ...
Page 11
... Heating up of the chip may require several milliseconds, depending on external conditions Figure 4a: Overtemperature: Reset if T < OUT T J Infineon Technologies AG Figure 5a: Open load: detection in ON-state, open load occurs in on-state L(SCr d(ST OL) Figure 5b: Open load: turn on/off to open load t Page 11 PROFET ® ...
Page 12
... Infineon Technologies 8.4 ±0.4 Office. Infineon Technologies Components may only be used in life- support devices or systems with the express written approval of Infineon Technologies failure of such components can reasonably be expected to cause the failure of that life-support device or system affect the ITS436L2 S safety or effectiveness of that device or system ...