Specifications of ITS 410E2

Packages
PG-TO220-5
Channels
1.0
Ron @ Tj = 25°c
220.0 mOhm (max)
Recommended Operating Voltage Range
4.7 - 42.0 V
Il(sc)
12.0 A
Diagnostic
Digital
Smart Highside Power Switch
for Industrial Applications
Features
Application
General Description
N channel vertical power FET with charge pump, ground referenced CMOS compatible input and diagnostic
feedback, monolithically integrated in Smart SIPMOS
1
Infineon Technologies AG
)
auto-restart and hysteresis
applications
Overload protection
Current limitation
Short circuit protection
Thermal shutdown
Overvoltage protection (including load dump)
Fast demagnetization of inductive loads
Reverse battery protection
Undervoltage and overvoltage shutdown with
Open drain diagnostic output
Open load detection in ON-state
CMOS compatible input
Loss of ground and loss of V
Electrostatic discharge (ESD) protection
All types of resistive, inductive and capacitve loads
Replaces electromechanical relays, fuses and discrete circuits
C compatible power switch with diagnostic feedback for 12 V and 24 V DC grounded loads in industrial
With external current limit (e.g. resistor R
connections, reverse load current limited by connected load.
4
2
ST
IN
ESD
Voltage
Voltage
sensor
source
Logic
V
1
)
Logic
bb
protection
Overvoltage
protection
Charge pump
Level shifter
Rectifier
1
GND
GND
Signal GND
=150 ) in GND connection, resistors in series with IN and ST
Product Summary
Overvoltage protection V
Operating voltage
On-state resistance
Load current (ISO)
Current limitation
Operating temperature T
1 of 15
Current
limit
technology. Providing embedded protective functions.
unclamped
Short circuit
Open load
ind. loads
detection
detection
Limit for
protection
Gate
Standard
PG-TO220AB/5
Temperature
sensor
PROFET ® ITS 410 E2
5
PROFET
V
R
I
I
L(ISO)
L(SCr)
a
bb(AZ)
bb(on)
ON
+ V bb
Straight leads
OUT
Load GND
3
5
-30…+85
4.7 ... 42
1
2006-Mar-28
Load
220 m
5
1.8
65
5
°C
V
V
A
A

Related parts for ITS 410E2

ITS 410E2 Summary of contents

Page 1

... IN Logic ESD With external current limit (e.g. resistor R connections, reverse load current limited by connected load. Infineon Technologies AG Product Summary Overvoltage protection V Operating voltage On-state resistance Load current (ISO) Current limitation Operating temperature T protection technology. Providing embedded protective functions. Overvoltage ...

Page 2

... V is setup without the DUT connected to the generator per ISO 7637-1 and DIN 40839 Load dump Infineon Technologies AG Function Logic ground Input, activates the power switch in case of logical high signal Positive power supply voltage, the tab is shorted to this pin Diagnostic feedback, low on failure ...

Page 3

... Leakage output current (included Operating current (Pin =-40...+150° supply voltage increase Meassured without load See also V . Infineon Technologies AG Symbol R T =25 ° =150 ° L(ISO) I L(GNDhigh see diagram 90 OUT ...

Page 4

... Note that the power dissipation is higher compared to normal operating conditions due to the voltage drop across the intrinsic drain-source diode. The temperature protection is not active during reverse current operation! Input and Status currents have to be limited (see max. ratings page 2 and circuit page 7). Infineon Technologies ...

Page 5

... Status output (open drain) Zener limit voltage T =-40...+150° low voltage T =-40...+150° ground resistor R is used, add the voltage drop across this resistor. GND Infineon Technologies AG Symbol =-40..+150° IN(T+) T =-40..+150° IN(T 0.4 V ...

Page 6

... PROFET GND GND R GND ) Power Transistor off, high impedance Low resistance short output may be detected in ON-state by the no-load-detection bb Infineon Technologies AG Output level level ...

Page 7

... Short circuit detection Fault Condition: V > 8.5 V typ.; IN high ON Short circuit Logic detection unit Inductive and overvoltage output clamp V Z GND V clamped typ. ON Infineon Technologies AG Overvolt. and reverse batt. protection + ESD 6.2 V typ Open-load detection ON-state diagnostic condition: V ...

Page 8

... OUT PROFET ST 4 GND other external inductive loads L are connected to the PROFET, additional elements like D are necessary. Infineon Technologies AG Inductive Load switch-off energy dissipation OUT 5 = Energy stored in load inductance: While demagnetizing load inductance, the energy dissipated in PROFET is OUT 5 with an approximate solution for R ...

Page 9

... Typ. transient thermal impedance chip case Z = f(t , D), D=t /T thJC [K/W] thJC 10 1 0.1 0.01 1E-5 1E-4 1E-3 1E-2 Infineon Technologies AG D= 0.5 0.2 0.1 0.05 0.02 0.01 0 1E-1 1E0 1E1 t p [s] 9 PROFET ® ITS 410 E2 2006-Mar-28 ...

Page 10

... With latch function. Reseted by a) Input low, b) Undervoltage ) No auto restart after overvoltage in case of short circuit 16 ) Low resistance short output may be detected in ON-state by the no-load-detection bb Infineon Technologies > typ bb 14 < after shutdown. In most cases ON(SC) 10 PROFET ® ITS ...

Page 11

... OUT A ST open drain A in case of too early V IN =high the device may not turn on (curve A) t approx. 150 s d(bb IN) Figure 2a: Switching a lamp OUT I L Infineon Technologies AG PROFET ® ITS 410 E2 Figure 2b: Switching an inductive load IN t d(ST OUT L(OL) ...

Page 12

... OUT Figure 3b: Turn on into overload L(SCp) I L(SCr) ST Heating up may require several seconds < 8.5 V typ. bb OUT Infineon Technologies AG PROFET ® ITS 410 E2 Figure 3c: Short circuit while on OUT I L **) t **) current peak approx Figure 4a: Overtemperature: Reset if T < ...

Page 13

... Figure 5b: Open load: detection in ON-state, open load occurs in on-state IN t d(ST OL1 OUT normal open tbd s typ tbd s typ d(ST OL1) d(ST OL2) Infineon Technologies AG Figure 6a: Undervoltage OUT ST open drain t Figure 6b: Undervoltage restart of charge pump d(ST OL2) V bb(u rst) normal V ...

Page 14

... V OUT ST Figure 9a: Overvoltage at short circuit shutdown bb(o rst) Output short to GND V OUT short circuit shutdown Overvoltage due to power line inductance. No overvoltage auto- restart of PROFET after short circuit shutdown. Infineon Technologies AG PROFET ® ITS 410 E2 V bb(o rst 2006-Mar-28 ...

Page 15

... Due to technical requirements components may contain dangerous substances. For information on the types in question please contact your nearest Infineon Technologies Office. Infineon Technologies Components may only be used in life- support devices or systems with the express written Ordering code approval of Infineon Technologies failure of such ...

Related keywords