Profiles 0-4 are not valid with the TEMAP device. Profiles 1-3, 5, 7 are not valid in the TECT3
device.
Interrupt-Service Routine Mask Vector
Passed via the
contains all the information needed by the driver to enable and disable any of the interrupts in the
TEMUX/TEMAP/TECT3.
Table 7: ISR Mask Vector: sTMX_MASK
Mask Sub-structures
These structures also appear in sTMX_MASK (above).
Table 8: IO Section Masks: struct tmx_mask_io
Field Name
sdet0e
sdet1e
io
ds3
mux[7]
framer[28]
mapper
Field Name
exsbi.ovre
exsbi.unde
insbi.ovre
insbi.unde
exsbi.pare
temuxClearMask
Field Type
UINT1
UINT1
struct tmx_mask_io
struct tmx_mask_ds3
struct tmx_mask_mux
struct tmx_mask_framer
struct tmx_mask_mapper
Field Type
UINT1
UINT1
UINT1
UINT1
UINT1
,
TEMUX/TEMAP/TECT3 (PM8315, PM5365, PM4328) Driver Manual
temuxGetMask
Field Description
SBI bus egress overrun
SBI bus egress underrun
SBI bus ingress overrun
SBI bus ingress underrun
SBI bus parity
and the
Sets / Clears Interrupt Condition
SBI collision detect (register 0)
SBI collision detect (register 1)
IO Section interrupts
DS3 Section interrupts
MUX/MX12/DS2 Section interrupts
FRAMER Section interrupts
MAPPER Section interrupts (not valid in
TECT3)
temuxSetMask
calls, this structure
Data Structures