PM5365 PMC-Sierra, Inc., PM5365 Datasheet - Page 76

no-image

PM5365

Manufacturer Part Number
PM5365
Description
TEMUX/TEMAP/TECT3 T1/E1 FRAMER, VT/TU MAPPER, M12/M13 MUX DRIVER MANUAL
Manufacturer
PMC-Sierra, Inc.
Datasheet
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
Document ID: PMC-1991611, Issue 2
Clearing/Setting MX23 Devices Loopbacks: temuxLoopMX23
This function clears or sets loopbacks within the MX23 section of the device. It is up to the user
to perform any tests on the looped data.
Returns
Valid States
Side Effects
Prototype
Inputs
Outputs
Returns
Valid States
Side Effects
Success =
Failure =
ACTIVE, INACTIVE
May inhibit the flow of active data
INT4 temuxLoopMX23 (sTMX_HNDL devId, UINT2
mxNum, UINT2 up, BOOLEAN ais)
devId
mxNum
up
ais
None
Success =
Failure =
ACTIVE, INACTIVE
May inhibit the flow of active data
TMX_ERR_CLOSED
TMX_ERR_INVALID
TMX_ERR_NOTREADY
TMX_ERR_ISPRESENT
TMX_ERR_ISSTART
TMX_ERR_ADDR
TMX_ERR_ARG
TMX_ERR_CLOSED
TMX_ERR_INVALID
TMX_ERR_NOTREADY
TMX_ERR_ISPRESENT
TMX_ERR_ISSTART
TMX_ERR_ADDR
TMX_ERR_ARG
TMX_ERR_HNDL
TMX_ERR_HNDL
TMX_OK
TMX_OK
TEMUX/TEMAP/TECT3 (PM8315, PM5365, PM4328) Driver Manual
: device handle (from
: framer number (1-7)
: up/down flag
: add AIS when looping up flag
temuxAdd
Application Programming Interface
)
76