SC-M01 Fuji Electric holdings CO.,Ltd, SC-M01 Datasheet
SC-M01
Related parts for SC-M01
SC-M01 Summary of contents
Page 1
... SC-M01/G 1NC 20 1NO SC-M02/G 1NC 20 1NO SC-M01/G1 1NC 20 1NO SC-M02/G1 1NC 20 1NO SC-M01/G2 1NC 20 1NO SC-M02/G2 1NC ■ Type number nomenclature SC-M01/G Operating coil Blank: AC operated G: 12–220V DC operated, power consumption 3W G1: 24V DC operated, power consumption 1.2W G2: 24V DC operated, power consumption 2W Max. motor capacity M01: 2.2kW at 380– ...
Page 2
... SC-M01RM/G 1NC × 1NO × SC-M02RM/G 1NC × 1NO × SC-M01RM/G1 1NC × 1NO × SC-M02RM/G1 1NC × 1NO × SC-M01RM/G2 1NC × 1NO × SC-M02RM/G2 1NC × ...
Page 3
... Us: Coil rated voltage • DC operated Type Power consumption (W) Inrush Sealed SC-M01 SC-M02/G SC-M01/G1 1.2 1.2 SC-M02/G1 SC-M01/ SC-M02/G2 * Note: Us: Coil rated voltage Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Operating cycles Voltage per hour 1200 200/240V AC ...
Page 4
... Type current contact arrangement (A) 20 1NO SC-M01 1NC 20 1NO SC-M02 1NC 20 1NO SC-M01/G 1NC 20 1NO SC-M02/G 1NC 20 1NO SC-M01/G1 1NC 20 1NO SC-M02/G1 1NC 20 1NO SC-M01/G2 1NC 20 1NO SC-M02/G2 1NC Breaking current (A) Information subject to change without notice 100 ...
Page 5
... SZ-MA13 SZ-MA04 SZ-MA20 SZ-MA11 SZ-MA02 SZ-MAS10 Front mounting SZ-MAS01 SZ-MA22 Used with SC-M01, SC-M02 SC-M01/G, SC-M02/G SC-M01/G1, SC-M02/G1 SC-M01/G2, SC-M02/G2 1NO 1NC 1NO 1NC 5NO 4NO+1NC 5NO 4NO+1NC – 4NO+1NC 3NO+2NC 4NO+1NC 3NO+2NC 3NO+2NC 2NO+3NC 3NO+2NC 2NO+3NC 2NO+3NC 1NO+4NC 2NO+3NC 1NO+4NC ...
Page 6
... Aux.terminal 1 56 (37.5)* M3.5 M3.5 42.3 7.5 7.6 2 (9.8 Front mounting aux. contact block 2 * Side mounting aux. contact block Mass : 0.36kg • Reversing/DC operated SC-M01RM/G, M01RM/G1, M01RM/G2 SC-M02RM/G, M02RM/G1, M02RM/G2 79(Mounting rail height 15) Main terminal Aux.terminal 1 68 (37.5)* M3.5 M3.5 54.3 7.5 7.6 2 (9.8 Front mounting aux. contact block 2 * Side mounting aux. contact block Mass : 0 ...
Page 7
... Aux. contact blocks / Side mounting SZ-MAS10, MAS01 56 9.8 45 7.6 Mass: 18g • Coil surge suppression unit SZ-MZ1, MZ2, MZ3 77.5 (SC-M01, M02) 89.5 (SC-M01/G, M02/G) 21.5 Mass: 5g Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice ■ Wiring diagrams 4NO Aux.terminal M3.5 ...
Page 8
... Power connection kit for reversing SZ-MRM Line 20.3 83.2 Mass: 27g • Solid-state time-delay unit SZ-MT2, MT5 88 (SC-M01, M02) 100 (SC-M01/G, M02/G) 32 Mass: 38g ■ Standard operating conditions Ambient Operating: –5 to 55˚C temperature No sudden temperature changes resulting in condensation or icing (The average temperature over a 24-hour period must not exceed 35˚ ...