LSM2-T30-D12 C&D Technologies., LSM2-T30-D12 Datasheet
LSM2-T30-D12
Related parts for LSM2-T30-D12
LSM2-T30-D12 Summary of contents
Page 1
... COMMON REFERENCE & V ERROR AMP OUT TRIM Typical topology is shown. Technical enquiries email: sales@murata-ps.com, tel: MDC_LSM2_T30_D12 Series.B11 Page 508 339 3000 ...
Page 2
... Load 125 15 25 ±0.2% ±0.4% 125 15 25 ±0.2% ±0.4% Nominal line voltage, no-load/full-load conditions. LSM2-T/30-D12 efficiencies are shown at V I max Amps with Vin = 0.8 to 3.6 Volts. With V out ➆ >3.63V, input range is 7-14V. out L SM2 T 30 D12 R - ...
Page 3
... The “R” pads and the standard pads 1 and 2 are in parallel. If your application uses a standard DOSA pad layout and you cannot con- nect to these ground pads, order model LSM2-T/30-D12-C without the “R” designator. Please observe the lower Derating curves for standard, “non-R” ...
Page 4
... V in out =2 x 100 µF tantalum, Cbus=1000 µF electrolytic, Lbus=1 µH. in Technical enquiries email: sales@murata-ps.com, tel: MDC_LSM2_T30_D12 Series.B11 Page =nominal out max ° =nominal (+5V), full load, external . ...
Page 5
... C) mounted close to Voltage Trim The LSM2 Series may also be trimmed using an external low-noise voltage applied between the Trim input and Output Common. Be aware that the inter- nal “load” impedance looking into Trim pin is below 1000 Ohms and includes factors from the output voltage. Therefore, use a low impedance source resistance in your external voltage reference ...
Page 6
... 2.66 4.31 5.97 7.62 9.28 10.9 12.6 14.2 Load C urre nt (Amps) LSM2-T/30-D12R Maximum Current Temperature Derating at Sea Level (V = 12V, Transverse Airflow). Extra ground pads installed. in 31.00 30.00 300 LFM 29.00 400 LFM 28.00 500 LFM 27.00 26.00 25.00 24.00 23.00 22.00 21.00 20.00 Natural Convection 19.00 100 LFM 18.00 200 LFM 17.00 16.00 15.00 14.00 13 ...
Page 7
... utput Current (Amps) LSM2-T/30-D12R Maximum Current Temperature Derating at Sea Level (V = 12V, Transverse Airflow). Extra ground pads installed. in 31.00 30.00 300 LFM 29.00 400 LFM 28 ...
Page 8
... utput C urre nt (Amps) LSM2-T/30-D12R Maximum Current Temperature Derating at Sea Level (V = 12V, Transverse Airflow). Extra ground pads installed. in 31.00 30.00 300 LFM 29.00 400 LFM 28.00 27.00 26.00 25.00 24.00 23.00 22.00 21.00 Natural Convection 100 LFM 20 ...
Page 9
... Load Current (Amps) LSM2-T/30-D12R Maximum Current Temperature Derating at Sea Level (V = 12V, Transverse Airflow). Extra ground pads installed. in 31.00 30.00 29.00 28.00 27.00 26.00 25.00 Natural Convection 24.00 ...
Page 10
... DOSA-SMT, 30A POL DC/DC Converters Output Ripple & Noise ( out C = 10µF || 1µF, ’scope MHz) out Power-On Startup ( out StepLoad Transient Response ( 0-15A-0) in Technical enquiries email: sales@murata-ps.com, tel: MDC_LSM2_T30_D12 Series.B11 Page 508 339 3000 ...
Page 11
... DOSA-SMT, 30A POL DC/DC Converters Output Ripple & Noise ( out C = 10µF || 1µF, ’scope MHz) out Power-On Startup ( out StepLoad Transient Response ( 0-15A-0) in Technical enquiries email: sales@murata-ps.com, tel: MDC_LSM2_T30_D12 Series.B11 Page 508 339 3000 ...
Page 12
... Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com Technical enquiries email: sales@murata-ps.com, tel: MDC_LSM2_T30_D12 Series.B11 Page 508 339 3000 ...