IHD260 CT-Concept Technologie AG, IHD260 Datasheet - Page 9

no-image

IHD260

Manufacturer Part Number
IHD260
Description
Data Sheet Ihd 260/660 Dual Channel Scale Igbt Driver Core
Manufacturer
CT-Concept Technologie AG
Datasheet
Short-circuit monitoring
Pin REF pull-up resistor to pin Cs
Pin REF source current
Pin ME pull-up resistor to pin Cs
Pin ME on-state source current
Pin ME off-state sink current
Pin ME off-state resistance
Pin REF on-state reference voltage
Command blocking
When a fault state has been cleared, the next turn-on commands are ignored by the ASIC during the
command blocking time to avoid thermal overload of the power MOSFET or IGBT driven by the gate
driver.
Command blocking time
Pins IN* Command Inputs
Logic level
Bias sink current
Pin capacitance
Pin SO* Status Outputs
Secondary-side faults cause the relevant channel to turn off immediately. Fault states are transmitted to
the primary side via the signal transformer interface (option T) or via an optocoupler (option C), in the
latter case with an additional delay. They are then reported at Pin SOA for channel A and at pin SOB for
channel B.
Available current at pins SO
Delay to report a fault state
I G B T - D r i v e r . c o m
Condition/remark
From Cs (note 5)
(Note 5)
From Cs (note 5)
Towards COM
Towards COM
Functional limits (note 5)
Condition/Remark
Factory-set
(other values upon request)
Condition/Remark
Positive-going threshold
Negative-going threshold
Condition/Remark
[V(VCC) – 1.2V] > V(SO+) > V(SO-)
Fault state
Otherwise
Option T:
during command blocking time
Option C
IHD260/660
Preliminary Data Sheet
Until next change in relevant IN*
1425
2090
1000
Min.
Min.
Min.
Min.
2.5
80
17
1500
2200
Typ.
Typ.
Typ.
Typ.
150
1.4
22
20
10
5
Max. Units
1575
2310
Max. Units
Max. Units
Max. Units
12.5
Page 9
125
27
1
3
1
mA
mA
mA
ms
μA
μA
μA
pF
μs
V
V
V

Related parts for IHD260