BD3883FS ROHM Co. Ltd., BD3883FS Datasheet - Page 15

no-image

BD3883FS

Manufacturer Part Number
BD3883FS
Description
Audio Sound Controller For Home Audio
Manufacturer
ROHM Co. Ltd.
Datasheet
13. Input Selector and Input Gain
14. Constraints of serial control (BD3883FS)
15. Function setting while muting Volume (BD3883FS)
MUTE setting example
When changing Input Selector or Input Gain, the Soft-switching is not applied. Therefore, it is recommended to
implement the MUTE function.
On Soft-switching of the RECOUT, Surround, and Rear Volume functions, data must not be sent serially to the
functions before the switching operation is completed.
While muting Volume, to avoid increasing residual noise, set Bass, Middle and Treble to 0dB, Surround to OFF, and
Rear Volume to -10dB.
MUTE
SERIAL DATA
INPUT SOURCE
SWITCHING
Direction
If the function for Soft-switch should serially send the data (Data(4)) on the
same Select Address, the time interval between the send operations must be
set to 500 -600msec.
Data(4)
40~60ms
Fig.17
15/16
Fig.18
T
SERIAL DATA
Data(4)
L=ON
H=OFF