Datasheet
Enhanced Digital Diagnostic Interface
The enhanced interface uses the two wire serial bus address 1010001X (A2h) to provide diagnostic
information about the module’s present operating conditions.
Note:
1) Write the password (11h, 11h, 11h, 11h) on the bytes of 123-126 of address A2h then the address of
DELTA ELECTRONICS, INC.
bytes 128-255 (User Writable) can be read and written.
The memory map in the following describes an extension to the memory map defined in SFP MSA.
127
128
255
95
96
0
2 wire address 1010000 X (A0h)
Serial ID Defined by SFP MSA
Digital Diagnostic Memory Map Specific Data Field Descriptions
Reserved in SFP MSA
Vender Specific
(128 bytes)
(96 bytes)
(32 bytes)
9
120
127
128
247
248
255
119
55
56
95
96
0
2 wire address 1010001 X (A2h)
Alarm and Warning Thresholds
Real Time Diagnostic Interface
User Writable EEPROM
Vender Specific(Note)
Vender Specific
Cal Constants
(120 bytes)
(56 bytes)
(40 bytes)
(24 bytes)
(8 bytes)