8.
Performance parameters of ZY8160 POL converters
can be programmed via the industry standard I
communication
components
parameter has a default value stored in the volatile
memory registers detailed in Table 1.
registers 00h through 14h are programmed at the
system power-up.
performance parameters, the values in the registers
are overwritten. Upon removal of the input voltage,
the default values are restored.
ZD-01674 REV. 1.1
Register
VOM
DON
DOF
RUN
VOS
TMP
DCL
C0H
C1H
C2H
C3H
PC1
PC2
PC3
CLS
C0L
C1L
C2L
C3L
IOM
INT
TC
ST
B1
B2
B3
Programmable Features
Table 1. ZY8160 Memory Registers
Dig Controller Denominator z
Dig Controller Denominator z
Dig Controller Denominator z
Interleave Configuration and
Dig Controller Numerator z
Dig Controller Numerator z
Dig Controller Numerator z
Dig Controller Numerator z
Dig Controller Numerator z
Dig Controller Numerator z
Dig Controller Numerator z
Dig Controller Numerator z
or
Protection Configuration 1
Protection Configuration 2
Protection Configuration 3
Output Voltage Monitoring
Output Current Monitoring
Temperature Monitoring
Output Voltage Setpoint
Tracking Configuration
Current Limit Setpoint
Coefficient, High Byte
Coefficient, High Byte
Coefficient, High Byte
Coefficient, High Byte
Coefficient, Low Byte
Coefficient, Low Byte
Coefficient, Low Byte
Coefficient, Low Byte
Frequency Selection
bus
rewiring
Duty Cycle Limit
Status Register
Turn-On Delay
Turn-Off Delay
RUN Register
When the user programs new
Coefficient
Coefficient
Coefficient
Content
without
PCB
traces.
replacing
-1
-1
-2
-2
-3
-3
0
0
-1
-2
-3
www.power-one.com
The setup
Address
0Ah
0Bh
0Ch
0Dh
0Eh
0Fh
00h
01h
02h
05h
06h
03h
04h
15h
16h
07h
08h
09h
10h
11h
12h
13h
14h
17h
18h
19h
Each
any
2
C
8V to 14V Input
ZY8160 converters can be programmed using the
Graphical User Interface or directly via the I
using high and low level commands as described in
the ‘”DPM Programming Manual”.
ZY8160 parameters can be reprogrammed at any
time during the system operation and service except
for the digital filter coefficients, the switching
frequency and the duty cycle limit, that can only be
changed when the POL output is turned off.
8.1
The output voltage can be programmed in the GUI
Output Configuration window shown in the Figure 17
or directly via the I
register shown in Figure 18.
ZY8160 60A DC-DC Intelligent POL
Bit 7:0 VOS[7:0], Output voltage setting
R/W-0
VOS7
Bit 7
Figure 18. Output Voltage Setpoint Register VOS
Output Voltage
00h: corresponds to 0.5000V
01h: corresponds to 0.5125V
77h: corresponds to 1.9875V
78h: corresponds to 2.0000V
79h: corresponds to 2.025V
96h: corresponds to 2.750V
Figure 17. Output Configuration Window
R/W-0
VOS6
R/W-0
VOS5
2
C bus by writing into the VOS
R/W-0
VOS4
0.5V to 2.75V Output
R/W-0
VOS3
Page 14 of 30
R/W-0
VOS2
R = Readable bit
W = Writable bit
U = Unimplemented bit,
- n = Value at POR reset
Data Sheet
read as ‘0’
R/W-0
VOS1
2
C bus by
R/W-0
VOS0
Bit 0