D4SL-NSK10-LKx Omron, D4SL-NSK10-LKx Datasheet - Page 11

no-image

D4SL-NSK10-LKx

Manufacturer Part Number
D4SL-NSK10-LKx
Description
Guard Lock Safety-door Switch
Manufacturer
Omron
Datasheet
Characteristics
Note: 1. The above values are initial values.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1).
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your OMRON
*3. Do not pass the 1 A, 125 VAC load through more than 3 circuits.
*4. These figures are minimum requirements for safe operation.
*5. This figure is based on the GS-ET-19 evaluation method.
*6. This value will vary with the switching frequency, environment, and reliability level.
Degree of protection *1
Durability *2
Operating speed
Operating frequency
Direct opening force *4
Direct opening travel *4
Holding force *5
Contact resistance
Minimum applicable load *6
Rated insulation voltage (Ui)
Rated frequency
Protection against electric shock
Pollution degree (operating environment)
Impulse
withstand voltage
(EN60947-5-1)
Insulation resistance
Vibration resistance
Shock resistance
Conditional short-circuit current
Conventional free air thermal current (Ith)
Ambient operating temperature
Ambient operations humidity
Weight
Confirm that sealing properties are sufficient for the operating conditions and environment beforehand.
Although the switch box is protected from dust, oil or water penetration, do not use the D4SL in places where cutting chips, oil, water or
chemicals may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
representative.
Confirm that correct operation is possible with the actual load beforehand.
2. The Switch contacts can be used with either standard loads or microloads.
Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads.
The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced.
Mechanical
Electrical
Between terminals of same polarity
Between terminals of different polarity
Between other terminals and
non-current carrying metallic parts
Malfunction
Malfunction
Destruction
IP67 (EN60947-5-1)
1,000,000 operations min.
150,000 operations min. (1 A resistance at 125 VAC) *3
0.05 to 1 m/s
5 operations minute max.
60 N min. (EN60947-5-1)
15 mm min. (EN60947-5-1)
1,300 N min.
200 mΩ max.
1 mA resistive load at 5 VDC (N-level reference value)
150 V (EN60947-5-1)
50/60 Hz
Class II (double insulation)
3 (EN60947-5-1)
1.5 kV
1.5 kV
2.5 kV
100 Ω min. (at 500 VDC)
10 to 55 Hz, 0.35 mm single amplitude
80 m/s
1,000 m/s
100 A (EN60947-5-1)
2.5A (11-42, 21-52, 21-22)
1A (Others)
−10 to 55°C (with no icing)
95% max.
Head: Resin
Head: Metal
Approx. 290 g (Connector model)
Approx. 330 g (Terminal block model)
Approx. 370 g (Connector model)
Approx. 410 g (Terminal block model)
www.DataSheet.co.kr
2
min.
2
min.
D4SL-N / D4SL-NSK10-LK@
11
Datasheet pdf - http://www.DataSheet4U.net/