XR16L570 Exar Corporation, XR16L570 Datasheet - Page 32
![no-image](/images/manufacturer_photos/0/2/243/exar_corporation_sml.jpg)
XR16L570
Manufacturer Part Number
XR16L570
Description
SMALLEST 1.62V TO 5.5V UART
Manufacturer
Exar Corporation
Datasheet
1.XR16L570.pdf
(46 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XR16L570IL24-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
Company:
Part Number:
XR16L570IL32-F
Manufacturer:
CYPRESS
Quantity:
101
Part Number:
XR16L570IL32-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
XR16L570
SMALLEST 1.62V TO 5.5V UART WITH 16-BYTE FIFO AND POWERSAVE
EFR[6]: Auto RTS Flow Control Enable
RTS# output may be used for hardware flow control by setting EFR bit-6 to logic 1. When Auto RTS is
selected, an interrupt will be generated when the receive FIFO is filled to the programmed trigger level and
RTS de-asserts to a logic 1 at one trigger level above the programmed trigger level. RTS# will return to a logic
0 when FIFO data falls below one trigger level below the programmed trigger level. The RTS# output must be
asserted (logic 0) before the auto RTS can take effect. RTS# pin will function as a general purpose output
when hardware flow control is disabled.
•
•
EFR[7]: Auto CTS Flow Control Enable
Automatic CTS Flow Control.
•
•
These registers are used as the programmable software flow control characters xoff1, xoff2, xon1, and xon2.
For more details, refer to
4.16
Logic 0 = Automatic RTS flow control is disabled (default).
Logic 1 = Enable Automatic RTS flow control.
Logic 0 = Automatic CTS flow control is disabled (default).
Logic 1 = Enable Automatic CTS flow control. Data transmission stops when CTS# input de-asserts to logic
1. Data transmission resumes when CTS# returns to a logic 0.
Software Flow Control Registers (XOFF1, XOFF2, XON1, XON2) - Write Only
“Section 2.15, Auto Xon/Xoff (Software) Flow Control” on page
32
xr
15.
REV. 1.0.0