AD1839 Analog Devices, AD1839 Datasheet - Page 18

no-image

AD1839

Manufacturer Part Number
AD1839
Description
2 ADC, 6 DAC 96 Khz, 24-Bit Sigma Delta Codec
Manufacturer
Analog Devices
Datasheet
AD1839
Register
Address
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
Address
15, 14, 13, 12 11
0000
Address R/9 RES Reserved Replicate
15, 14,
13, 12
0001
11
0
R/9
0
10
0
Register
Name
DACCTRL1
DACCTRL2
DACVOL1
DACVOL2
DACVOL3
DACVOL4
DACVOL5
DACVOL6
RES
RES
ADCPeak0
ADCPeak1
ADCCTRL1
ADCCTRL2
ADCCTRL3
Reserved
9
0
RES
10
0
De-emphasis
9, 8
00 = None
01 = 44.1 kHz
10 = 32.0 kHz
11 = 48.0 kHz
PRELIMINARY TECHNICAL DATA
Stereo
8
0 = Off
1 = Replicate
Description
DAC Control 1
DAC Control 2
DAC Volume - Left 1
DAC Volume - Right 1
DAC Volume - Left 2
DAC Volume - Right 2
DAC Volume - Left 3
DAC Volume - Right 3
Reserved
Reserved
ADC Left Peak
ADC Right Peak
ADC Control 1
ADC Control 2
ADC Control 3
Reserved
Reserved Reserved OUTR3
7
0
DAC Data
Format
7, 6, 5
000 = I
001 = RJ
010 = DSP
011 = LJ
100 = Pack Mode 256
101 = Reserved
110 = Reserved
111 = Reserved
Table III. Control Register Map
Table IV. DAC Control I
Table V. DAC Control II
2
S
6
0
–18–
FUNCTION
Type
R/
R/
R/
R/
R/
R/
R/
R/
R/
R/
R
R
R/
R/
R/
R/
5
0 = On
1 = Mute 1 = Mute 1 = Mute 1 = Mute 1 = Mute 1 = Mute
FUNCTION
DAC Data
4, 3
00 = 24 Bits
01 = 20 Bits
10 = 16 Bits
11 = Reserved
Word Width
MUTE DAC
10
10
10
10
10
10
10
10
10
10
6
6
10
10
10
10
Width
OUTL3
4
0 = On
Reset
000
000
3FF
3FF
3FF
3FF
3FF
3FF
Reserved
Reserved
000
000
000
000
000
Reserved
Setting (Hex)
2
0 = Normal
1 = Power-Down
Power Down
Reset
OUTR2
3
0 = On
OUTL2
2
0 = On
Sample Rate
1, 0
00 = 8x (48 k)
01 = 4x (96 k)
10 = 2x (192 kHz)
11 = 8x (48 k)
OUTR1
1
0 = On
REV. PrD
OUTL1
0
0 = On

Related parts for AD1839