MODEL232BSS4 B&B Electronics, MODEL232BSS4 Datasheet - Page 12

no-image

MODEL232BSS4

Manufacturer Part Number
MODEL232BSS4
Description
Buffered Smart Switch
Manufacturer
B&B Electronics
Datasheet
Note: The 232BSS4 ignores the upper 4 bits of the control byte. If
the Master device is incapable of sending characters outside the
printable ASCII range, decimal 64 can be added to each of the
control bytes and the switch will operate properly.
Ignore Commands – “T” + one control byte specifying the length of
time to ignore commands.
10
Clear Receive Buffer
Ports to Transmit or
all commands from the Master device for a specific amount of
time. This command is useful if the data coming from the Master
device may contain switching commands. By switching to a port,
then sending the Ignore Commands command, all data received
on the Master port of the 232BSS4 will be passed directly to the
selected Slave port without checking for a command sequence
until the programmed time has elapsed. The control byte at the
end of the command tells the 232BSS4 how long to ignore
commands from the Master device. This byte is ASCII “0” – “9”
(48 – 57 Decimal). Timer values for each Control byte are given
in Table 2.3.
Table 2.2: Send Only and Clear Buffer Control Characters
A, B, C, & D
A, C, & D
B, C, & D
A, B, & C
A, B, & D
The Ignore Commands command tells the 232BSS4 to ignore
A Only
B Only
C Only
D Only
C & D
A & C
B & C
A & D
B & D
A & B
None
(x = Don’t Care)
Binary Value
xxxx0000
xxxx0001
xxxx0010
xxxx0011
xxxx0100
xxxx0101
xxxx0110
xxxx0111
xxxx1000
xxxx1001
xxxx1010
xxxx1011
xxxx1100
xxxx1101
xxxx1110
xxxx1111
Documentation Number 232BSS41202 Manual
10 or 74
11 or 75
12 or 76
13 or 77
14 or 78
15 or 79
Decimal
0 or 64
1 or 65
2 or 66
3 or 67
4 or 68
5 or 69
6 or 70
7 or 71
8 or 72
9 or 73
Value
Character
ASCII
“@”
“M”
“C”
“D”
“G”
“H”
“N”
“O”
“A”
“B”
“E”
“K”
“F”
“L”
“J”
“I”

Related parts for MODEL232BSS4