ISL6141 Intersil Corporation, ISL6141 Datasheet - Page 12

no-image

ISL6141

Manufacturer Part Number
ISL6141
Description
Negative Voltage Hot Plug Controller
Manufacturer
Intersil Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ISL6141CB-T
Manufacturer:
LSIOGIC
Quantity:
218
Part Number:
ISL6141CBZ
Manufacturer:
INTERSIL
Quantity:
20 000
Part Number:
ISL6141IB
Quantity:
6
Part Number:
ISL6141IB
Manufacturer:
INTERSIL
Quantity:
20 000
Part Number:
ISL6141IBZ
Manufacturer:
INTERSIL
Quantity:
20 000
Part Number:
ISL6141IBZA
Manufacturer:
Intersil
Quantity:
500
Part Number:
ISL6141IBZA
Manufacturer:
INTERSIL
Quantity:
20 000
Inrush Current Control
The primary function of the ISL6141 hot plug controller is to
control the inrush current. When a board is plugged into a
live backplane, the input capacitors of the board’s power
supply circuit can produce large current transients as they
charge up. This can cause glitches on the system power
supply (which can affect other boards!), as well as possibly
cause some permanent damage to the power supply.
The key to allowing boards to be inserted into a live
backplane is to turn on the power to the board in a controlled
manner, usually by limiting the current allowed to flow
through a FET switch, until the input capacitors are fully
charged. At that point, the FET is fully on, for the smallest
voltage drop across it. Figure 25 below illustrates the typical
inrush current response resulting from a hot insertion for the
following conditions:
• V
• C1 = 150nF, C2 = 3.3nF, R3 = 18k
• I
• C
After the contact bounce subsides the UVLO and UV criteria
are quickly met and the GATE begins to ramp up. As the
GATE reaches approximately 4V with respect to the source,
the FET begins to turn on allowing current to charge the load
capacitor. As the drain to source voltage begins to drop, the
feedback network of C2 and R3 hold the GATE constant, in
this case limiting the current to approximately 1.3A. When
the DRAIN voltage completes its ramp down the load current
remains constant at 320mA as the GATE voltage increases
to its final value.
FIGURE 25. INRUSH CURRENT LIMITING FOR A HOT
Inrush
EE
L
= 100uF, R
= -48V, Rsense = 0.02 (2.5A current limit)
= 50 A (100 F/3.3nF) = 1.5A
INSERTION
L
= 150 (48V/150 = 320mA)
12
ISL6141, ISL6151
Electronic Circuit Breaker/Current Limit
The ISL6141/51 features programmable current limiting with a
fixed 600 s time-out period to protect against excessive
supply or fault currents. The IntelliTrip
breaker is capable of detecting both hard faults, and less
severe Over-Current conditions.
The Over-Current trip point is determined by R1 (Eq. #3) also
referred to as Rsense. When the voltage across this resistor
exceeds 50mV, the current limit regulator will turn on, and the
GATE will be pulled lower (to ~4V) to regulate current through
the FET at 50mV/Rsense. If the fault persists and current
limiting exceeds the 600 s time-out period, the FET will be
turned off by discharging the GATE pin to V
enable the Over-Current latch and the PWRGD/PWRGD
output will transition to the inactive state to indicate power is
no longer good. To clear the latch and initiate a normal power-
up sequence, the user must either power down the system
(below the UVLO voltage), or toggle the UV pin below and
above its threshold (usually with an external transistor). Figure
26 below shows the Over-Current shut down and current
limiting response for a 10 short to ground on the output. With
a 10 short and a -48V supply, the initial fault current is
approximately 4.8A, producing a voltage drop across the
0.02 sense resistor of 95mV, roughly two times the Over-
Current threshold of 50mV. This enables the 600 s timer and
the GATE is quickly pulled low to limit the current to 2.5A
(50mV/Rsense). The fault condition persists for the duration of
the time-out period and the GATE is latched off in about
670 s. There is a short filter (3 s nominal) on the comparator,
so current transients shorter than this will be ignored. Longer
transients will initiate the GATE pull down, current limiting,
and the timer. If the fault current goes away before the time-
out period expires the device will exit the current limiting mode
and resume normal operation.
FIGURE 26. CURRENT LIMITING AND TIMEOUT