R15-600-RNLD Norgren, R15-600-RNLD Datasheet - Page 18

no-image

R15-600-RNLD

Manufacturer Part Number
R15-600-RNLD
Description
Olympian Filter
Manufacturer
Norgren
Datasheet
Typical Performance Characteristics
Ordering Information.
and 0,3 to 10 bar (5 to 150 psig) outlet pressure adjustment range* without gauge.
Alternative Models
*
**
For replacement Filter/Regulator (without yoke) substitute ‘0’ at 4th and ‘O’ at 10th digits eg: B15-096-F3LO.
N/AL.8.261.300.02
Adjustment
Knob
T-bar
Port Size
3/4 "
1 "
1 1/4 "
1 1/2 "
Option
With sight glass, relieving
Without sight glass, relieving
With sight glass, non relieving
Without sight glass, non relieving
Port Size
G3/4
G1
G1 1/4
G1 1/2
100
Outlet pressure can be adjusted to
pressures in excess of, and less than,
those specified. Do not use these units to
control pressures outside of the specified
ranges.
Units with 17 bar (250 psig) adjustment
range are available only with the T-bar
adjustment; therefore substitute ‘A’ at the
1st digit and ‘S’ at the 9th position.
80
60
40
20
0
8
6
4
2
0
0
0
B15
100
50
200
FLOW CHARACTERISTICS
100
Models listed include ISO G threads, knob adjustment, automatic drain, 50 µm element, relieving diaphragm
We reserve the right to amend, without notice, the specifications given in this document.
Substitute
Substitute
Substitute
UNPORTED
INLET PRESSURE - 10 bar g (150 psig)
RANGE: 0,4 to 8 bar (5 to 120 psig)
AIR FLOW
300
Model
B15-696-F3LD
B15-896-F3LD
B15-A96-F3LD
B15-B96-F3LD
9 6
2 4
9 8
2 6
B
A**
A
B
6
8
150
Our policy is one of continuous research and development.
400
200
B 1
500
5
250
-
dm
scfm
3
/s
-
PTF
ISO Rc taper
ISO G parallel
Outlet Pressure Adjustment Range*
0 to 4 bar (0 to 60 psig)
0,4 to 8 bar (5 to 120 psig)
0,7 to 17 bar (10 to 250 psig)
Element
25 µm
50 µm
Drain
Automatic
Manual
Thread
5 µm
Weight kg (lb)
3,16 (7.02)
3,12 (6.93)
3,14 (6.98)
3,18 (7.07)
Substitute
Substitute
Substitute
Substitute
D
A
B
F
L
S**
1
2
3
F
B
7/97

Related parts for R15-600-RNLD