SC16C752BIBS Philips Semiconductors, SC16C752BIBS Datasheet - Page 25

no-image

SC16C752BIBS

Manufacturer Part Number
SC16C752BIBS
Description
5 V/ 3.3 V and 2.5 V dual UART/ 5 Mbit/s (max.)/ with 64-byte FIFOs
Manufacturer
Philips Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC16C752BIBS
Manufacturer:
NXP Semiconductors
Quantity:
1 909
Part Number:
SC16C752BIBS
Manufacturer:
NXP
Quantity:
1 618
Part Number:
SC16C752BIBS
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
SC16C752BIBS151
Manufacturer:
NXP Semiconductors
Quantity:
135
Philips Semiconductors
9397 750 14443
Product data
7.6 Modem control register (MCR)
Remark: The three error bits (parity, framing, break) may not be updated correctly in
the first read of the LSR when the input clock (XTAL1) is running faster than 36 MHz.
However, the second read is always correct. It is strongly recommended that when
using this device with a clock faster than 36 MHz, that the LSR be read twice and only
the second read be used for decision making. All other bits in the LSR are correct on
all reads.
The MCR controls the interface with the mode, data set, or peripheral device that is
emulating the modem.
Table 14:
[1]
Bit
7
6
5
4
3
2
1
0
MCR[7:5] can only be modified when EFR[4] is set, i.e., EFR[4] is a write enable.
Symbol
MCR[7]
MCR[6]
MCR[5]
MCR[4]
MCR[3]
MCR[2]
MCR[1]
MCR[0]
Modem Control Register bits description
5 V, 3.3 V and 2.5 V dual UART, 5 Mbit/s (max.), with 64-byte FIFOs
Rev. 03 — 14 December 2004
[1]
[1]
[1]
Description
Clock select.
TCR and TLR enable.
Xon Any.
Enable loop-back.
IRQ enable OP.
FIFO Ready enable.
RTS
DTR
Table 14
Logic 0 = Divide-by-1 clock input.
Logic 1 = Divide-by-4 clock input.
Logic 0 = no action.
Logic 1 = Enable access to the TCR and TLR registers.
Logic 0 = Disable Xon Any function.
Logic 1 = Enable Xon Any function.
Logic 0 = Normal operating mode.
Logic 1 = Enable local loop-back mode (internal). In this mode the
MCR[3:0] signals are looped back into MSR[7:4] and the TX output
is looped back to the RX input internally.
Logic 0 = Forces INTA-INTB outputs to the 3-State mode and OP
output to HIGH state.
Logic 1 = Forces the INTA-INTB outputs to the active state and OP
output to LOW state. In loop-back mode, controls MSR[7].
Logic 0 = Disable the FIFO Rdy register.
Logic 1 = Enable the FIFO Rdy register.
In loop-back mode, controls MSR[6].
Logic 0 = Force RTS output to inactive (HIGH).
Logic 1 = Force RTS output to active (LOW).
In loop-back mode, controls MSR[4]. If Auto-RTS is enabled, the
RTS output is controlled by hardware flow control.
Logic 0 = Force DTR output to inactive (HIGH).
Logic 1 = Force DTR output to active (LOW).
In loop-back mode, controls MSR[5].
shows modem control register bit settings.
© Koninklijke Philips Electronics N.V. 2004. All rights reserved.
SC16C752B
25 of 47

Related parts for SC16C752BIBS