sfp-dro12d-ir1 MRV Communications, Inc., sfp-dro12d-ir1 Datasheet - Page 3

no-image

sfp-dro12d-ir1

Manufacturer Part Number
sfp-dro12d-ir1
Description
622 Mbps Dual Rate Single-mode 25 Km Sfp Transceivers
Manufacturer
MRV Communications, Inc.
Datasheet
Datasheet
Notes:
Recommended Operating Conditions
Parameter
Operating Case Temperature
Power Supply Voltage
Power Supply Current
Power dissipation
Data Rate
Pin Descriptions
Pin
10
11
12
13
14
15
16
17
18
19
20
1
2
3
4
5
6
7
8
9
1.
2.
3.
4.
5.
6.
TX Fault is an open collector output, which should be pulled up with a 4.7 k~10 kΩ resistor on the host board to a voltage between 2.0 V and
Vcc+0.3V. Logic 0 indicates normal operation; logic 1 indicates a laser fault of some kind. In the low state, the output will be pulled to less than 0.8 V.
TX Disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7 k~10 kΩ resistor.
Its states are:
Low (0~0.8 V):
(>0.8V, <2.0V):
High (2.0~3.465V):
Open:
MOD-DEF 0,1,2 are the module defi nition pins. They should be pulled up with a 4.7 k~10 kΩ resistor on the host board. The pull-up voltage shall
be VccT or VccR.
MOD-DEF 0 is grounded by the module to indicate that the module is present
MOD-DEF 1 is the clock line of two wires serial interface for serial ID
MOD-DEF 2 is the data line of two wires serial interface for serial ID
LOS is an open collector output, which should be pulled up with a 4.7 k~10 kΩ resistor on the host board to a voltage between 2.0 V and
Vcc+0.3V. Logic 0 indicates normal operation; logic 1 indicates loss of signal. In the low state, the output will be pulled to less than 0.8 V.
These are the diff erential receiver output. They are internally AC-coupled 100 Ω diff erential lines which should be terminated with 100 Ω
(diff erential) at the user SERDES.
These are the diff erential transmitter inputs. They are AC-coupled, diff erential lines with 100 Ω diff erential termination inside the module.
MOD-DEF2
MOD-DEF1
MOD-DEF0
Rate Select
Tx Disable
Function
Tx Fault
Optical Communications Systems™
VeeR
VeeR
VeeR
VeeR
VeeT
VccR
VccT
VeeT
VeeT
RD+
TD+
LOS
RD-
TD-
Transmitter on
Undefi ned
Transmitter Disabled
Transmitter Disabled
Symbol
V
DR
I
T
P
CC
CC
D
C
Inverted Transmitter Data In
Transmitter Fault Indication
Inverted Received Data Out
Loss of Signal Indication
Module Defi nition 2
Module Defi nition 1
Module Defi nition 0
Transmitter Ground
Transmitter Ground
Transmitter Ground
Name/Description
Transmitter Disable
Transmitter Data In
Received Data Out
Transmitter Power
Receiver Ground
Receiver Ground
Receiver Ground
Receiver Ground
Not Connected
Receiver Power
3
Minimum
3.13
155
-5
-
-
Maximum
3.47
300
622
70
1
Plug Seq.
Mbps
Unit
mA
ºC
W
V
1
3
3
3
3
3
3
3
1
1
1
3
3
1
2
2
1
3
3
1
Note
Note
1
2
3
3
3
4
5
5
6
6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-

Related parts for sfp-dro12d-ir1