ds26519 Maxim Integrated Products, Inc., ds26519 Datasheet - Page 176

no-image

ds26519

Manufacturer Part Number
ds26519
Description
Ds26519 16-port T1/e1/j1 Transceiver
Manufacturer
Maxim Integrated Products, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS26519
Manufacturer:
DS
Quantity:
6 203
Part Number:
DS26519
Manufacturer:
MAXIM
Quantity:
16 248
Part Number:
ds26519GN
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
ds26519GN+
Manufacturer:
MAXIM
Quantity:
430
Part Number:
ds26519GN+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
ds26519GNA2
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
ds26519GNA2+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
This register will report the received Sa6 codeword per ETS 300 233. The bits are monitored on a submultiframe
asynchronous basis, so the pattern reported could be one of multiple patterns that would represent a valid
codeword. The table below indicates which patterns reported in this register correspond to a given valid Sa6
codeword.
Bits 3 to 0: Sa6 Codeword Bit (Sa6n)
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
Bit 7: Framer Enable (FRM_EN). This bit must be set to the desired state before writing INIT_DONE.
Bit 6: Initialization Done (INIT_DONE). The user must set this bit once he has written the configuration registers.
The host is required to write or clear all device registers prior to setting this bit. Once INIT_DONE is set, the
DS26519 will check the FRM_EN bit and, if enabled, will begin operation based on the initial configuration.
Bit 1: Soft Reset (SFTRST). Level sensitive “soft” reset. Should be taken high, then low to reset the receiver.
Note: This reset does not clear the registers.
Bit 0: Receiver T1/E1 Mode Select (T1/E1). Sets operating mode for receiver only! This bit must be set to the
desired state before writing INIT_DONE.
VALID Sa6 CODE
0 = Framer disabled—held in low-power state.
1 = Framer enabled—all features active.
0 = Normal operation.
1 = Reset the receiver.
0 = T1 operation.
1 = E1 operation.
Sa6_C
Sa6_A
Sa6_E
Sa6_F
Sa6_8
FRM_EN
7
0
7
0
INIT_DONE
Sa6CODE
Received Sa6 Codeword Register
06Fh + (200h x (n - 1)) + (2000h x [(n - 1) / 8]): where n = 1 to 16
RMMR
Receive Master Mode Register
080h + (200h x (n - 1)) + (2000h x [(n - 1) / 8]): where n = 1 to 16
6
0
6
0
POSSIBLE REPORTED
1000, 0100, 0010, 0001
1110, 0111, 1011, 1101
110, 0110, 0011, 1001
PATTERNS
1010, 0101
5
0
1111
5
0
176 of 310
4
0
4
0
Sa6n
3
0
3
0
DS26519 16-Port T1/E1/J1 Transceiver
Sa6n
2
0
2
0
SFTRST
Sa6n
1
0
1
0
Sa6n
T1/E1
0
0
0
0

Related parts for ds26519