Setup and assembly of the light barriers
It must not be possible:
- to crawl under the lowest beam,
- to climb over the highest beam or
- to walk between two beams
To calculate the minimum distance of the photoelectric sensor from the hazardous area, please refer to the
applicable requirements and standards.
Sending unit
Minimum interval S
Danger zone
Protective field
Receiving unit
Safety light barriers should be arranged so that the transmitters
connected to the various SC2 light barrier modules cannot di-
rect beams at the receivers of other control units.
Safety light barriers must be mounted in such a manner that it
is not possible to reach the hazardous area by bypassing the
protective beams.
Figure 4.1:Minimum distance between the electrosensitive pro-
tection device and the hazardous area
Setup and assembly of the light barriers
Copyright Pepperl+Fuchs, Printed in Germany
SC2-2 control unit
17