ltc2978 Linear Technology Corporation, ltc2978 Datasheet - Page 54

no-image

ltc2978

Manufacturer Part Number
ltc2978
Description
Octal Pmbus Power Supply Monitor And Controller With Eeprom
Manufacturer
Linear Technology Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LTC2978
Manufacturer:
TEMIC
Quantity:
73
Part Number:
ltc2978A
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
ltc2978ACUP
Manufacturer:
LTNEAR
Quantity:
20 000
Part Number:
ltc2978ACUP#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
ltc2978ACUP#TRPBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Company:
Part Number:
ltc2978ACUP#TRPBF
Quantity:
493
Part Number:
ltc2978AIUP
Manufacturer:
LTNRAR
Quantity:
20 000
Part Number:
ltc2978CUKH#PBF
Manufacturer:
LT
Quantity:
680
Part Number:
ltc2978CUP
Manufacturer:
LT
Quantity:
357
Part Number:
ltc2978CUP
Quantity:
6 218
Part Number:
ltc2978CUP#PBF
Manufacturer:
LINEAR
Quantity:
16 050
Company:
Part Number:
ltc2978CUP#TRPBF
Quantity:
48
Interconnect Between Multiple LTC2978s
Figure 14 shows how to interconnect the pins in a typical
multi-LTC2978 array.
• All V
• Connecting all V
LTC2978
applicaTions inForMaTion

connection at the point where V
This will minimize timing errors for the case where the
ON_OFF_CONFIG is configured to start the LTC2978
based on V
OPERATION command. In multi-part applications that
are sensitive to timing errors, it is recommended that
the Vin_share_enable bit of the MFR_CONFIG_ALL
register be set high in order to allow SHARE_CLK to
synchronize on/off sequencing in response to the V
and V
overvoltage (OV) fault on any DC/DC converter’s output
in the array to shut off a common input switch.
IN_SNS
IN_OFF
IN
lines should be tied together in a star type
thresholds.
and ignore the CONTROLn line and the
IN_EN
lines together will allow an
LTC2978 1
Figure 14. Typical Connections Between Multiple LTC2978s
SHARE_CLK
WDI/RESET
CONTROL0
CONTROL1
GND
FAULTB00
FAULTB01
FAULTB10
FAULTB11
VIN_SNS
ALERTB
PWRGD
IN
VIN_EN
SDA
SCL
is to be sensed.
TO OTHER LTC2978s–10k EQUIV PULL-UP RECOMMENDED
TO V
ON EACH LINE EXCEPT SHARE_CLK (USE 5.49k)
DC/DCs
IN
OF
TO HOST CONTROLLER
IN_ON
• ALERTB is typically one line in an array of PMBus
• WDI/RESET can be used to put the LTC2978 in the
• The FAULTBzn lines can be connected together to create
• PWRGD reflects the status of the outputs that are
converters. The LTC2978 allows a rich combination of
faults and warnings to be propagated to the ALERTB
pin.
power-on reset state. Pull WDI/RESET low for at least
t
fault dependencies. Figure 14 shows a configuration
where a fault on any FAULTBzn will pull all others low.
This is useful for arrays where it is desired to abort a
startup sequence in the event any channel does not
come up (see Figure 15).
mapped to it by the MFR_PWRGD_EN command. Fig-
ure 14 shows all the PWRGD pins connected together,
but any combination may be used.
RESETB
TO INPUT
SWITCH
to enter this state.
VIN_SNS
VIN_EN
SDA
SCL
ALERTB
CONTROL0
CONTROL1
WDI/RESET
FAULTB00
FAULTB01
FAULTB10
FAULTB11
SHARE_CLK
PWRGD
LTC2978 #n
GND
2978 F14
2978fa