ltc3729euh-trpbf Linear Technology Corporation, ltc3729euh-trpbf Datasheet - Page 12

no-image

ltc3729euh-trpbf

Manufacturer Part Number
ltc3729euh-trpbf
Description
550khz, Polyphase, High Efficiency, Synchronous Step-down Switching Regulator
Manufacturer
Linear Technology Corporation
Datasheet
APPLICATIO S I FOR ATIO
LTC3729
When using the controller in very low dropout conditions,
the maximum output current level will be reduced due to
internal slope compensation required to meet stability
criterion for buck regulators operating at greater than 50%
duty factor. A curve is provided to estimate this reduction
in peak output current level depending upon the operating
duty factor.
Operating Frequency
The LTC3729 uses a constant frequency, phase-lockable
architecture with the frequency determined by an internal
capacitor. This capacitor is charged by a fixed current plus
an additional current which is proportional to the voltage
applied to the PLLFLTR pin. Refer to Phase-Locked Loop
and Frequency Synchronization in the Applications Infor-
mation section for additional information.
A graph for the voltage applied to the PLLFLTR pin vs
frequency is given in Figure 2. As the operating frequency
is increased the gate charge losses will be higher, reducing
efficiency (see Efficiency Considerations). The maximum
switching frequency is approximately 550kHz.
Inductor Value Calculation and Output Ripple Current
The operating frequency and inductor selection are inter-
related in that higher operating frequencies allow the use
of smaller inductor and capacitor values. So why would
12
Figure 2. Operating Frequency vs V
2.5
2.0
1.5
1.0
0.5
0
200
U
250
OPERATING FREQUENCY (kHz)
300
U
350
400
W
450
PLLFLTR
500
3729 F02
550
U
anyone ever choose to operate at lower frequencies with
larger components? The answer is efficiency. A higher
frequency generally results in lower efficiency because of
MOSFET gate charge and transition losses. In addition to
this basic tradeoff, the effect of inductor value on ripple
current and low current operation must also be consid-
ered. The PolyPhase approach reduces both input and
output ripple currents while optimizing individual output
stages to run at a lower fundamental frequency, enhancing
efficiency.
The inductor value has a direct effect on ripple current. The
inductor ripple current
decreases with higher inductance or frequency and in-
creases with higher V
where f is the individual output stage operating frequency.
In a PolyPhase converter, the net ripple current seen by the
output capacitor is much smaller than the individual
inductor ripple currents due to the ripple cancellation. The
details on how to calculate the net output ripple current
can be found in Application Note 77.
Figure 3 shows the net ripple current seen by the output
capacitors for the different phase configurations. The
output ripple current is plotted for a fixed output voltage as
the duty factor is varied between 10% and 90% on the
x-axis. The output ripple current is normalized against the
inductor ripple current at zero duty factor. The graph can
be used in place of tedious calculations. As shown in
Figure 3, the zero output ripple current is obtained when:
So the number of phases used can be selected to minimize
the output ripple current and therefore the output ripple
voltage at the given input and output voltages. In applica-
tions having a highly varying input voltage, additional
phases will produce the best results.
V
V
OUT
I
L
IN
V
OUT
fL
N
k
1
where k = 1, 2, …, N – 1
V
V
OUT
IN
IN
or V
I
L
OUT
per individual section, N,
:
sn3729 3729fas

Related parts for ltc3729euh-trpbf