max5970 Maxim Integrated Products, Inc., max5970 Datasheet - Page 9

no-image

max5970

Manufacturer Part Number
max5970
Description
0v To 16v, Dual Hot-swap Controller With 10-bit Current And Voltage Monitor And 4 Led Drivers
Manufacturer
Maxim Integrated Products, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
max5970ETX
Manufacturer:
M/A-COM
Quantity:
5 000
0V to 16V, Dual Hot-Swap Controller with 10-Bit
Current and Voltage Monitor and 4 LED Drivers
PIN
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
SENSE2
FAULT1
FAULT2
GATE2
ALERT
RETRY
NAME
HWEN
DGND
MODE
MON2
DREG
GND2
LED1
LED2
LED4
LED3
ON1
SDA
ON2
POL
SCL
PG1
PG2
EP
_______________________________________________________________________________________
LED Driver 1
LED Driver 2
Polarity Select Input. Connect to DREG for active-high power-good outputs (PG_). Connect to GND for
active-low power-good outputs.
Logic Power-Supply Input. Connect to REG externally through a 10I resistor and to DGND with a 1FF
ceramic capacitor.
Channel 1 Precision Turn-On Input
Channel 1 Active-Low Open-Drain Fault Output. FAULT1 goes low if an overcurrent occurs on channel 1.
Channel 2 Active-Low Open-Drain Fault Output. FAULT2 goes low if an overcurrent occurs on channel 2.
I
I
Open-Drain Alert Output. ALERT goes low during a fault to notify the system of an impending failure.
Channel 1 Open-Drain Power-Good Output
Channel 2 Open-Drain Power-Good Output
Hardware Enable Input. Connect to DREG or DGND. State is read upon power-up as V
UVLO threshold and sets enable register bits with this value. After UVLO, this input becomes inactive until
power is cycled.
Digital Ground. Connect all GND_ and DGND to AGND externally using a star connection.
Channel 2 Precision Turn-On Input
Autoretry Fault Management Input. Connect to DREG to enable autoretry operation. Connect to DGND to
enable latched-off operation.
Hot-Swap Two-State Mode Select Input. Connect MODE to DGND, DREG or leave it unconnected to oper-
ate the hot-swap channels independently or as a pair.
LED Driver 4
LED Driver 3
Channel 2 Gate Discharge Current Ground Return. Connect all GND_ and DGND to AGND externally
using a star connection.
Channel 2 Gate-Drive Output. Connect to gate of an external n-channel MOSFET.
Channel 2 Voltage Monitoring Input
Channel 2 Current-Sense Input. Connect SENSE2 to the source of an external MOSFET and to one end of
R
Exposed Pad. EP is internally grounded. Connect externally to ground plane using a star connection.
2
2
SENSE2
C Serial-Data Input/Output
C Serial-Clock Input
.
FUNCTION
Pin Description (continued)
IN
crosses the
9

Related parts for max5970