adt7320ucpz-rl7 Analog Devices, Inc., adt7320ucpz-rl7 Datasheet - Page 21

no-image

adt7320ucpz-rl7

Manufacturer Part Number
adt7320ucpz-rl7
Description
Manufacturer
Analog Devices, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADT7320UCPZ-RL7
Manufacturer:
FSC
Quantity:
3 400
INT AND CT OUTPUTS
The INT and CT pins are open-drain outputs, and both pins
require a 10 kΩ pull-up resistor to V
UNDERTEMPERATURE AND OVERTEMPERATURE
DETECTION
The INT and CT pins have two undertemperature/overtemperature
modes: comparator mode and interrupt mode. The interrupt
mode is the default power-up overtemperature mode. The INT
output pin becomes active when the temperature is greater than
the temperature stored in the T
the temperature stored in the T
pin reacts after this event depends on the overtemperature
mode selected.
Figure 19 illustrates the comparator and interrupt modes for
events exceeding the T
Figure 20 illustrates the comparator and interrupt modes for
events exceeding the T
Rev. PrB
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
HIGH
LOW
limit with both pin polarity settings.
limit with both pin polarity settings.
HIGH
LOW
setpoint register. How this
setpoint register or less than
DD
.
±0.5°C Accurate, 12-Bit Digital
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
Fax: 781.461.3113
Comparator Mode
In comparator mode, the INT pin returns to its inactive status
when the temperature drops below the T
rises above the T
Putting the ADT7320 into shutdown mode does not reset the
INT state in comparator mode.
Interrupt Mode
In interrupt mode, the INT pin goes inactive when any ADT7320
register is read. When the INT pin is reset, it goes active again
only when the temperature is greater than the temperature stored
in the T
in the T
Placing the ADT7320 into shutdown mode resets the INT pin
in interrupt mode.
HIGH
LOW
setpoint register.
setpoint register or less than the temperature stored
LOW
Temperature Sensor
+ T
©2010 Analog Devices, Inc. All rights reserved.
HYST
limit.
HIGH
− T
ADT7320
www.analog.com
HYST
limit or

Related parts for adt7320ucpz-rl7