s-8242bar-t8t1g Seiko Instruments Inc., s-8242bar-t8t1g Datasheet - Page 11

no-image

s-8242bar-t8t1g

Manufacturer Part Number
s-8242bar-t8t1g
Description
Battery Protection Ic For 2-serial-cell Pack
Manufacturer
Seiko Instruments Inc.
Datasheet
Rev.1.7
Remark Refer to “
1. Normal Status
2. Overcharge Status
Operation
This IC monitors the voltage of the battery connected between the VDD and VSS pins and the voltage difference
between the VM and VSS pins to control charging and discharging. When the battery voltage is in the range from
overdischarge detection voltage n (V
range from the charger detection voltage (V
charging and discharging control FETs on. This condition is called the normal status, and in this condition charging
and discharging can be carried out freely.
Caution When the battery is connected for the first time, discharging may not be enabled. In this case,
When the battery voltage becomes higher than overcharge detection voltage n (V
status and detection continues for the overcharge detection delay time (t
charging control FET off to stop charging. This condition is called the overcharge status.
The overcharge status is released in the following two cases ((1) and (2)).
(1) When the battery voltage falls below overcharge release voltage n (V
(2) When a load is connected and discharging starts, the S-8242B Series turns the charging control FET on and
Caution 1. If the battery is charged to a voltage higher than overcharge detection voltage n (V
_00
control FET on and returns to the normal status.
returns to the normal status. Just after the load is connected and discharging starts, the discharging current
flows through the parasitic diode in the charging control FET. At this moment the VM pin potential becomes V
the voltage for the parasitic diode, higher than the V
detection voltage n (V
the S-8242B Series releases the overcharge condition.
2. When a charger is connected after overcharge detection, the overcharge status is not released
short the VM pin and VSS pin or connect the charger to restore the normal status.
battery voltage does not fall below overcharge detection voltage n (V
load is connected, overcurrent 1 and overcurrent 2 do not function until the battery voltage falls
below overcharge detection voltage n (V
of tens of mΩ, the battery voltage drops immediately after a heavy load that causes overcurrent
is connected, and overcurrent 1 and overcurrent 2 function.
even if the battery voltage is below overcharge release voltage n (V
is released when the VM pin voltage goes over the charger detection voltage (V
the charger.
Battery Protection IC Connection Example ”.
CUn
) and provided that the VM pin voltage is higher than overcurrent detection voltage 1,
BATTERY PROTECTION IC FOR 2-SERIAL-CELL PACK
DLn
) to overcharge detection voltage n (V
Seiko Instruments Inc.
CHA
) to overcurrent detection voltage 1 (V
CUn
SS
). Since an actual battery has an internal impedance
level. When the battery voltage goes under overcharge
CU
CLn
) or longer, the S-8242B Series turns the
), the S-8242B Series turns the charging
CUn
), and the VM pin voltage is in the
CUn
) during charging in the normal
CLn
IOV1
). The overcharge status
CUn
), the IC turns both the
) even when a heavy
S-8242B Series
CHA
) by removing
CUn
) and the
11
f
,

Related parts for s-8242bar-t8t1g