Page 1
... Data Sheet Dual Power Distribution Controller The HIP1012 is a HOT SWAP dual supply power distribution controller. Two external N-Channel MOSFETs are driven to distribute power while providing load fault isolation. At turn-on, the gate of each external N-Channel MOSFET is charged with current source. Capacitors on each gate (see the Typical Application Diagram), create a programmable ramp (soft turn-on) to control inrush currents ...
Page 2
... DD R ENABLE PWRON1 RISING EDGE RESET 12V PWRON2 ENABLE 3X 12V FALLING + - EDGE 10 A DELAY CLIM 5VG 5VS HIP1012 R SENSE TO LOAD 12ISEN 12V 100 A R ILIM R ILIM POR GND QPUMP 12V PUMP C PUMP TIM C TIM + - + OC LATCH ...
Page 3
... The current at current limit onset is equal SENSE R ). The HIP1012 is limited to a 10k min value (OC Vth = 100mV) resistor whereas SENSE the HIP1012A can accommodate a 5k resistor for a lower OC Vth (50mV). Connect to the load side of sense resistor to measure the voltage drop across this resistor. ...
Page 4
... VUV V12VG C = 0.1 F PUMP V R =10k IL5V ILIM HIP1012A only ILIM 3XV R =10k IL5V ILIM HIP1012A only ILIM 200% Current Overload, R ILIM R = 2.5 SHORT 200% Current Overload, R ILIM R = 2.5 SHORT 200% Current Overload, R ILIM R = 2.5 SHORT 0.01 F SHORT VG = 220 F, ESR = 0 ...
Page 5
... HIP1012 turns soft start mode protecting the supply rail from sudden current loading. If either PWRON pin is pulled low the HIP1012 will be in true hot swap mode. Both PWRON pins must be high to turn off the HIP1012 thus isolating the power supply from the load through the external FETs ...
Page 6
... See block diagram for OC latch off circuit suggestion. The HIP1012 is reset by a rising edge on either PWRON pin and is turned on by either PWRON pin being driven low. The HIP1012 can control either +12V/5V or +3.3V/+5V supplies. ...
Page 7
... TEMPERATURE ( FIGURE 1. SUPPLY CURRENT 10.7 10.6 10.5 10.4 10.3 -40 -30 -20 - TEMPERATURE ( FIGURE 3. C CURRENT SOURCE TIM 11.00 10.98 10.96 10.94 -40 - TEMPERATURE ( FIGURE 5. 12V UV THRESHOLD 7 HIP1012, HIP1012A 105 104 103 102 - 2.04 2.02 2.00 1.98 1. 4.615 4.610 4.605 4.600 4.595 40 60 ...
Page 8
... VG 17.28 17.26 -40 - TEMPERATURE ( C) FIGURE 7. 12V, 3/5V GATE DRIVE 54.5 54 Vth 53 Vth 53.0 52.5 -40 - TEMPERATURE ( FIGURE 9. OC VOLTAGE THRESHOLD WITH R 8 HIP1012, HIP1012A (Continued) 11.935 17.6 11.930 17.4 11.925 17.2 11.920 11.915 17.0 11.910 16.8 11.905 11.900 16 102.5 102.0 101.5 101.0 100 FIGURE 10 ...
Page 9
... HIP1012 GENERIC board in its default configuration (3V and 5V) a dedicated +12V power supply must be provided for the HIP1012 through tie point the generic board. To operate the board in the +12V and 5V mode, JP2 and JP3 need to be reconfigured (see Table 3) and a suitable current load needs to be provided ...
Page 10
... HIP1012EVAL1 Board Components CEC1 3 /12VIN GND GND JP1 0 NOTE: Test point number equals HIP1012 pin number. CEF SW13 CEF 1,2,3 R102 SW14 LED2 CEF 4,5,6, 7,8,10 SW11 CEF 9,11, 12 R103 SW12 LED3 LOAD BOARD 10 HIP1012, HIP1012A 20m ...
Page 11
... BUS FIGURE 13. HIP1012EVAL1 EVAL BOARD GENERIC LOAD ...
Page 12
... DD See Table 3 for jumper configuration descriptions Lit indicates a fault condition Tie point for dedicated +12V HIP1012 supply, use in default configuration Modify edge connector finger lengths for power sequencing Switch and load resistor pair to invoke high current load on 5V Switch and load resistor pair to invoke low current load on 5V Switch and load resistor pair to invoke high current load on 3 ...
Page 13
... In this configuration, PWRON1 is available to reset the HIP1012 in case of an over-current trip. Otherwise the HIP1012 can be reset by toggling the voltage on V JP2 removed, the circuit is controlled using one or both of the PWRON signal lines. The HIP1012EVAL2 is shipped with both jumpers installed ...
Page 14
... JP2 12VG CTIM PWRON1 PWRON2 PGOOD 5VG GND 0.01 F RF1K49157 Q1 FIGURE 14. HIP1012 EVALUATION CIRCUIT FOR DISK DRIVE HOT PLUG 14 HIP1012, HIP1012A R 2 0.020 Q2 1% RF1K49157 0. 0 HIP1012 1 14 3/12VS 3/12ISEN ...
Page 15
... For information regarding Intersil Corporation and its products, see web site www.intersil.com Sales Office Headquarters NORTH AMERICA Intersil Corporation P. O. Box 883, Mail Stop 53-204 Melbourne, FL 32902 TEL: (321) 724-7000 FAX: (321) 724-7240 15 HIP1012, HIP1012A M14.15 14 LEAD NARROW BODY SMALL OUTLINE PLASTIC PACKAGE SYMBOL A ...