hcs166ms Intersil Corporation, hcs166ms Datasheet
hcs166ms
Related parts for hcs166ms
hcs166ms Summary of contents
Page 1
... Input Current Levels VOL, VOH Description The Intersil HCS166MS is an 8-bit shift register that has fully synchronous serial or parallel data entry selected by an active LOW Parallel Enable (PE) input. When the PE is LOW one setup time before the LOW-to-HIGH clock transition, parallel data is entered into the register ...
Page 2
... ENABLE ENABLE High Level L = Low Level X = Immaterial = Transition from low to high level HCS166MS TRUTH TABLE INPUTS PARALLEL CLOCK SERIAL The level of steady state input at inputs D0 thru D7, respectively. ...
Page 3
... Functional Test VIH = 0.70(VCC), VIL = 0.30(VCC), (Note 2) NOTES: 1. All voltages reference to device GND. 2. For functional tests, VO 4.0V is recognized as a logic “1”, and VO Specifications HCS166MS Reliability Information Thermal Resistance SBDIP Package 10mA Ceramic Flatpack Package . . . . . . . . . . . 25mA Maximum Package Power Dissipation at +125 SBDIP Package ...
Page 4
... The parameters listed in Table 3 are controlled via design or process parameters. Min and Max Limits are guaranteed but not directly tested. These parameters are characterized upon initial design release and upon design changes which affect these characteristics. Specifications HCS166MS GROUP (NOTES 1, 2) ...
Page 5
... AC measurements assume RL = 500 , CL = 50pF, Input 3ns, VIL = GND, VIH = VCC. 3. For functional tests, VO 4.0V is recognized as a logic “1”, and VO TABLE 5. BURN-IN AND OPERATING LIFE TEST, DELTA PARAMETERS (+25 PARAMETER ICC IOL/IOH Specifications HCS166MS (NOTES 1, 2) CONDITIONS TEMPERATURE 0.5V is recognized as a logic “0”. GROUP B SUBGROUP ...
Page 6
... Each pin except VCC and GND will have a resistor of 1K OPEN 13 NOTE: Each pin except VCC and GND will have a resistor of 47K Group E, Subgroup 2, sample size is 4 dice/wafer 0 failures. Specifications HCS166MS TABLE 6. APPLICABLE SUBGROUPS METHOD GROUP A SUBGROUPS 100%/5004 ...
Page 7
... Variables Data (All Delta operations). Data is identified by serial number. Data header includes lot number and date of test. • The Certificate of Conformance is a part of the shipping invoice and is not part of the Data Book. The Certificate of Conformance is signed by an authorized Quality Representative. HCS166MS 100% Interim Electrical Test 1 (T1) 100% Delta Calculation (T0-T1) 100% Static Burn-In 2, Condition hrs ...
Page 8
... However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries. For information regarding Intersil Corporation and its products, see web site http://www.intersil.com HCS166MS tf MR ...
Page 9
... D1 (3) D2 (4) D3 (5) CE (6) (7) CP NOTE: The die diagram is a generic plot from a similar HCS device intended to indicate approximate die size and bond pad location. The mask series for the HCS166 is TA14386A. HCS166MS HCS166MS D0 DS VCC (2) (1) (16) (8) (9) (10) GND ...