hcs193ms Intersil Corporation, hcs193ms Datasheet
hcs193ms
Related parts for hcs193ms
hcs193ms Summary of contents
Page 1
... VIH = 0.70% VCC Min • Input Current Levels VOL, VOH Description The Intersil HCS193MS is a Radiation Hardened 4-bit binary UP/ DOWN synchronous counter. Presetting the counter to the number on the preset data inputs (P0 - P3) is accomplished by a low on the asynchronous parallel load input (PL). The counter is incremented on the low to high ...
Page 2
... CPU FF0 CPD 8 GND 16 VCC 3 Q0 FUNCTION CLOCK UP Count Up Count Down H Reset X Load Preset Inputs High Level Low Level Immaterial, HCS193MS FF1 FF2 TRUTH TABLE CLOCK DOWN H ...
Page 3
... Functional Test VIH = 0.70(VCC), VIL = 0.30(VCC), (Note 2) NOTES: 1. All voltages reference to device GND. 2. For functional tests VO 4.0V is recognized as a logic “1”, and VO Specifications HCS193MS Reliability Information Thermal Resistance SBDIP Package 10mA Ceramic Flatpack Package . . . . . . . . . . . 25mA Maximum Package Power Dissipation at +125 SBDIP Package ...
Page 4
... CIN Output Transition Time TTHL TTLH Maximum Operating Frequency FMAX (CPU, CPD) Setup Time TSU Hold Time Hold Time CPD to CPU or CPU to TH CPD Specifications HCS193MS GROUP (NOTES SUB- CONDITIONS GROUPS TEMPERATURE 9 10, 11 +125 9 10, 11 +125 9 ...
Page 5
... TPLH TPHL TPHL NOTES: 1. All voltages referenced to device GND measurements assume RL = 500 , CL = 50pF, Input 3ns, VIL = GND, VIH = VCC. 3. For functional tests VO 4.0V is recognized as a logic “1”, and VO Specifications HCS193MS (NOTE 1) CONDITIONS TW VCC = 4.5V TW VCC = 4.5V TW VCC = 4.5V VCC = 4.5V VCC = 4 ...
Page 6
... Each pin except VCC and GND will have a resistor of 10K 2. Each pin except VCC and GND will have a resistor of 1K OPEN 12, 13 NOTE: Each pin except VCC and GND will have a resistor of 47K E, Subgroup 2, sample size is 4 dice/wafer 0 failures. Specifications HCS193MS GROUP B SUBGROUP 5 5 TABLE 6. APPLICABLE SUBGROUPS ...
Page 7
... Sales Office Headquarters NORTH AMERICA Intersil Corporation P. O. Box 883, Mail Stop 53-204 Melbourne, FL 32902 TEL: (321) 724-7000 FAX: (321) 724-7240 HCS193MS 100% Interim Electrical Test 1 (T1) 100% Delta Calculation (T0-T1) 100% Static Burn-In 2, Condition hrs. min., o +125 C min., Method 1015 ...
Page 8
... FIGURE 5. SETUP AND HOLD TIMES DATA TO PARALLEL LOAD (PL) AC Timing Diagrams AC VOLTAGE LEVELS PARAMETER HCS VCC 4.50 VIH 4.50 VS 2.25 VIL 0 GND 0 HCS193MS INPUT LEVEL CPU OR CPD VS TPHL TPLH TCU OR TCD VS FIGURE 2. CLOCK TO TERMINAL COUNT DELAYS INPUT LEVEL MR INPUT LEVEL VS TREC INPUT CPU OR CPD ...
Page 9
... Thickness: 13k 2.6k WORST CASE CURRENT DENSITY < 2 A/cm BOND PAD SIZE: 100 m x 100 m 4 mils x 4 mils Metallization Mask Layout Q0(3) CPD(4) CPU(5) Q2(6) Q3(7) HCS193MS HCS193MS Q1 P1 VCC (2) (1) (16) (8) (9) (10 GND 278 (15) P0 (14) MR (13) TCD (12) TCU (11) PL 518759 ...