acpl-w60l-520e Avago Technologies, acpl-w60l-520e Datasheet
![no-image](/images/manufacturer_photos/0/0/85/avago_technologies_sml.jpg)
acpl-w60l-520e
Related parts for acpl-w60l-520e
acpl-w60l-520e Summary of contents
Page 1
... RoHS 6 fully compliant options available; -xxxE denotes a lead-free product Description The ACPL-W60L/K63L are optically coupled gates that combine a GaAsP light emitting diode and an integrated high gain photo detector. The output of the detector open collector Schottky-clamped transistor. The internal shield provides a guaranteed common mode transient immunity specification of 15 kV/µ ...
Page 2
... Combination of Option 020 and Option 060 is not available. Example 1: ACPL-W60L-560E to order product of Stretched SO-6 Surface Mount package in Tape and Reel packaging with IEC/EN/DIN EN 60747-5-2 Safety Approval in RoHS compliant. Option datasheets are available. Contact your Avago sales representative or authorized distributor for information. ...
Page 3
... ACPL-K63L Stretched SO-8 Package 0.381 ± 0.13 (0.015 ± 0.005 7° 0.450 (0.018) 45° 0.200 ± 0.100 (0.008 ± 0.004) 6.807 ± ...
Page 4
... T = 150 °C smax smin Note: Non-halide flux should be used. Regulatory Information The ACPL-W60L/K63L have been approved by the following organizations: UL Approval under UL 1577, Component Recognition Program, File E55361. CSA Approval under CSA Component Acceptance Notice #5, File CA 88324. IEC/EN/DIN EN 60747-5-2 ...
Page 5
Insulation and Safety Related Specifications Parameter Symbol Minimum External Air L (101) Gap (External Clearance) Minimum External Tracking L (102) (External Creepage) Minimum Internal Plastic Gap (Internal Clearance) Tracking Resistance CTI (Comparative Tracking Index) Isolation Group IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics Description Installation classification ...
Page 6
Absolute Maximum Ratings (No Derating Required up to 85˚C) Parameter Storage Temperature Operating Temperature† Average Forward Input Current Reverse Input Voltage Input Power Dissipation Supply Voltage (1 Minute Maximum) Output Collector Current Output Collector Voltage Output Power Dissipation Solder Reflow Temperature Profile **Ratings apply to all devices except ...
Page 7
Electrical Specifications Over Recommended Operating Conditions (T All Typicals 3 25˚ Parameter Sym. Device High Level Output Current Input Threshold I TH Current Low Level Output Voltage ...
Page 8
Switching Specifications Over Recommended Temperature (T All Typicals 25˚ 3 Parameter Sym. Propagation Delay t PLH Time to High Output Level Propagation Delay t PHL Time to Low Output Level Pulse Width ...
Page 9
... ACPL-W60L H Level Common ACPL-K63L Mode Transient Immunity Output Low |CM | ACPL-W60L L Level Common ACPL-K63L Mode Transient Immunity Output High |CM | ACPL-W60L H Level Common ACPL-K63L Mode Transient Immunity Output Low |CM | ACPL-W60L L Level Common ACPL-K63L Mode Transient Immunity 9 Min. Typ. Units Test Conditions 15 25 kV/ 3 ...
Page 10
Package Characteristics All Typicals 25˚C. A Parameter Sym. Package Input-Output I * Single I-O Insulation Input-Output V Single, ISO Momentary Dual Channel Withstand Voltage* Input-Output R Single, I-O Resistance Dual Channel Input-Output C Single, I-O Capacitance Dual Channel ...
Page 11
250 µA = 250 µ -60 -60 ...
Page 12
-60 -40 - – TEMPERATURE – °C A Figure 4. Typical low level output current vs. temperature. SINGLE CHANNEL I F PULSE ...
Page 13
... For product information and a complete list of distributors, please go to our web site: Avago, Avago Technologies, and the A logo are trademarks of Avago Technologies, Limited in the United States and other countries. Data subject to change. Copyright © 2007 Avago Technologies Limited. All rights reserved. Obsoletes AV01-0206EN ...