tl0324s Newhaven Display International, Inc, tl0324s Datasheet - Page 10

no-image

tl0324s

Manufacturer Part Number
tl0324s
Description
65com / 132seg Driver & Controller For Stn Lcd
Manufacturer
Newhaven Display International, Inc
Datasheet
Table 5-3. Parallel data transfer
d. Serial interface (PS = "L")
When the TL0324S is active and serial interface has been selected, the serial data (DB7) and the serial clock
(DB6) inputs are enabled.
And TL0324S is not active, the internal 8-bit shift register and the 3-bit counter are reset.
The serial data can be read on the rising edge of the serial clock going into DB6 and processed as 8-bit
parallel data on the eighth serial clock.
The serial data input is display data when RS is high and control data when RS is low.
Since the clock signal (DB6) is easy to be affected by the external noise caused by the line length, the
operation check on the actual machine is recommended.
e. Busy flag
The busy flag indicates whether the TL0324S is operating or not.
When DB7 is “H” in read status operation, this device is in busy status and will accept only read status
instruction.
If the cycle time is correct, the MPU needs not to check this flag before each instruction, which improves
the MPU performance.
TOMATO LSI Inc.
Common
RS
/CS1
CS2
SID
(DB7)
SCLK
(DB6)
RS
TL0324S
H
H
L
L
E_/RD
(E)
H
H
H
H
6800-series
DB7
RW_/WR
(RW)
H
H
L
L
DB6
Figure 5-1. Serial interface timing
DB5
E_/RD
(/RD)
H
H
L
L
8080-series
DB4
10
65COM / 132SEG DRIVER & CONTROLLER FOR STN LCD
DB3
RW_/WR
(/WR)
H
H
L
L
DB2
Writes to internal register(instruction)
DB1
Display data read out
Register status read
DB0
Display data write
Description
DB7
DB6
Ver 0.1

Related parts for tl0324s