tca0g156k8r ROHM Co. Ltd., tca0g156k8r Datasheet - Page 4

no-image

tca0g156k8r

Manufacturer Part Number
tca0g156k8r
Description
Chip Tantalum Capacitors With Open-function Built-in
Manufacturer
ROHM Co. Ltd.
Datasheet
Tantalum capacitors
Temperature
Stability
Surge voltage
Loading at
High temperature
Terminal
strength
Item
Temp.
ΔC / C
Df (tan δ)
L.C.
Temp.
ΔC / C
Df (tan δ)
L.C.
Temp.
ΔC / C
Df (tan δ)
L.C.
Appearance
L.C.
ΔC / C
Df (tan δ)
Appearance
L.C.
ΔC / C
Df (tan δ)
Capacitance
Appearance
TCA0G686
TCA0G107
Others
−55 °C
Within 0/−12% of initial value
Shall be satisfied the voltage on " Standard list "
+85 °C
TCA0G686
TCA0G107
TCA0J686
Shall be satisfied the voltage on " Standard list "
5μA or 0.1CV whichever is greater
+125 °C
Within
Shall be satisfied the voltage on " Standard list "
6.3μA or 0.125CV whichever is greater
There should be no significant abnormality.
Shall be satisfied the voltage on " Standard list "
TCA0G686
TCA0G107
TCA0J686
Less than initial limit
There should be no significant abnormality.
TCA1E105
TCA1A226
TCA0G686
TCA0G107
TCA0J476
Less than initial limit
The measured value should be stable.
There should be no significant abnormality.
Others
Others
TCA0J686
TCA0J686
TCA1A226
Others
+15/0%
: Less than 125% of initial limit
: Less than 125% of initial limit
: Less than 125% of initial limit
: Less than 125% of initial limit
: Less than 125% of initial limit
: Less than initial limit
:
: Within
: Within
: Within
: Within
: Within
: Within
: Within
: Within
: Within
: Within
: Within
: Within
:
±10%
±10%
of initial value
Performance
of initial value
of initial value
+12/0%
+12/0%
+12/0%
+10/0%
±15%
±20%
±20%
±15%
±20%
±15%
±15%
±20%
of initial value
of initial value
of initial value
of initial value
of initial value
of initial value
of initial value
of initial value
of initial value
of initial value
of initial value
of initial value
Test conditions (based on JIS C 5101−1 and JIS C 5101− 3)
As per 4.29 JIS C 5101-1
As per 4.13 JIS C 5101-3
As per 4.26JIS C 5101-1
As per 4.14JIS C 5101-3
Apply the specified surge voltage every 5±0.5 min.
for 30±5 s. each time in the atmospheric condition of 85±2°C.
Repeat this procedure 1,000 times.
After the specimens, leave it at room temperature for
over 24h and then measure the sample.
As per 4.23 JIS C 5101-1
As per 4.15 JIS C 5101-3
After applying the rated voltage for 2000+72/0 h without
discontinuation via the serial resistance of 3Ω or less
at a temperature of 85±2°C, leave the sample at room
temperature / humidity for over 24h and measure the value.
As per 4.35 JIS C 5101-1
As per 4.9 JIS C 5101-3
A force is applied to the terminal until it bends to 1mm and
by a prescribed tool maintain the condition for 5s.
(See the figure below)
thickness=1.6mm
50
45
TC Series A Case
R230
20
45
F (Apply force)
(Unit : mm)
Rev.D
1
4/11