mn1382s Panasonic Corporation of North America, mn1382s Datasheet

no-image

mn1382s

Manufacturer Part Number
mn1382s
Description
Volyage Detector Ic
Manufacturer
Panasonic Corporation of North America
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mn1382s-N(TX)
Manufacturer:
RFMD
Quantity:
100
Part Number:
mn1382s-N(TX)
Manufacturer:
PANASONIC/松下
Quantity:
20 000
Company:
Part Number:
mn1382s-N(TX)
Quantity:
2 400
Company:
Part Number:
mn1382s-N(TX)
Quantity:
2 400
Part Number:
mn1382sGP
Manufacturer:
Panasonic - SSG
Quantity:
1 916
Part Number:
mn1382sJP
Manufacturer:
Panasonic - SSG
Quantity:
135
Volyage Detector IC
MN1382S
CMOS IC for Voltage Detection
 Overview
to microcomputers and other LSI systems and issue reset signals for initializing
the system after the power is first applied or for preventing runaway operation
when the supply voltage fluctuates.
the series' wide selection of detection ranks (16 ranks 2.0 V to 4.7 V).
inverted CMOS output (MN13822S).
 Features
 Applications
 Block Diagram
Note) *1 : Circuits vary slightly depending on the output type (CMOS output, N-channel open drain output, or inverted CMOSoutput)
Publication date: November 2007
 Three-pin element requiring no adjustment
 Wide selection of detection ranks (16 ranks 2.0 V to 4.7 V)
 Highly precise detection voltage
 Detection voltage with hysteresis characteristic
 Low current consumption: I
 Low fluctuation in detection voltage with tempera-ture (1 mV/°C (typ.))
 Battery checkers
 Power outage detectors
 Level discriminators
 Memory backup systems
 Microcomputer reset circuits
 Reset circuits for other electronic circuits
∆VD = 50 mV
∆VD = 100 mV for ranks L to T
The MN1382S are elements that monitor the power supply voltage supplied
This is a CMOS output, choose the ideal element for your application from
There is other output type, N-channel open drain output (MN13821S) and
for ranks C to K
Voltage
Reference 1
Voltage
Reference 2
Level Converter
DD
= 1 µA (typ.) for V
This product complies with the RoHS Directive (EU 2002/95/EC).
DD
= 5 V
Comparator
Comparator
+
+
SAG00006AED
 Package
 Code
 Pin name
MINI-3DC
1: Out
2: V
3: V
Note) Rank symbol will be marked on the
* 1
Output Circuit
SS
DD
package in the
Reset signal output pin
Ground pin
Power supply pin
1
SC
3
3
1
2
 area.
2
V
OUT
V
DD
SS
1

Related parts for mn1382s

mn1382s Summary of contents

Page 1

... MN1382S CMOS IC for Voltage Detection  Overview The MN1382S are elements that monitor the power supply voltage supplied to microcomputers and other LSI systems and issue reset signals for initializing the system after the power is first applied or for preventing runaway operation when the supply voltage fluctuates. ...

Page 2

... Power supply voltage V  Application Circuit Example Sample Circuit MN1382S Note) Connect resistors, capacitors, and the like only to the output pin on the MN1382S element. Note that connect-ing them to the power source pins changes V 2 Detection Voltage Hysteresis Width ∆VD DL Unit Max 2 ...

Page 3

... See Figures 2 and SAG00006AED MN1382S Min Typ Max Unit 1 5 µA V For particulars, see the detection voltage rank table Allowable Value (typ) Unit 3.0 µs 4.0 250.0 115.0 µ ...

Page 4

... Time lag between the time that the power supply voltage reaches the detection voltage ( 6 6.0 V CMOS output MN1382S 1 Figure 2. Description chart of Measuring the Output Characteristics 4 MN1382S Figure 1. Description of Operation and the time that theoutput pin (OUT) goes to Low level and the time that theoutput pin (OUT) goes to High level ...

Page 5

... Note) 1. Output cannot be specified for power supply voltages under 1.5 V because operation is not guaranteed for that range Detection voltage for drop in power supply voltage Detection voltage for rise in power supply voltage DH MN1382S 1 SAG00006AED MN1382S 100 pF V OUT ∆ ...

Page 6

... This product complies with the RoHS Directive (EU 2002/95/EC). MN1382S  Reference Characteristics The following characteristics curves represent results from a specific sample therefore they do not guarantee thecharacteristics for the final product. 1.4 1.2 1.0 0.8 0.6 0.4 0 1.0 2.0 Figure 5-a I  2.0 1.5 1.0 0.5 −40 −20 0 Temperature Characteristic Figure 6-a I  Temperature Characteristic (Rank Q) ...

Page 7

... Temperature Characteristic Figure7-a V  V Temperature Characteristic (Rank 0.3 0.25 0.2 0.15 0.1 0.05 0 –40 −20 0 Temperature Characteristic Figure 8-a ∆VD Temperature Characteristic (Rank (°C) a Figure 7-b Measurement Circuit (°C) a Figure 8-b Measurement Circuit SAG00006AED MN1382S V OUT OUT ...

Page 8

... This product complies with the RoHS Directive (EU 2002/95/EC). MN1382S  Reference Characteristics (Continued) The following characteristics curves represent results from a specific sample therefore they do not guarantee thecharacteristics for the final product 0.5 1.0 Figure 9 −30°C Room temperature 15 80°C ...

Page 9

... The following characteristics curves represent results from a specific sample therefore they do not guarantee thecharacteristics for the final product. 2.5 2.0 1.5 1.0 0.5 0 −40 −20 0 Temperature Characteristic Figure 11 7.0 6.5 6.0 5.5 5.0 4.5 0 −40 −20 Temperature Characteristic Figure 12 (°C) a  Temperature Characteristic (°C) a  Temperature Characteristic SAG00006AED MN1382S V OUT 1 Figure 11-b Measurement Circuit V OUT Figure 12-b Measurement Circuit 9 ...

Page 10

... This product complies with the RoHS Directive (EU 2002/95/EC). MN1382S MINI-3DC 1 (0.95) 1.9 2.90 10 +0.10 0.40 −0. (0.95) ±0.1 +0.20 −0.05 SAG00006AED +0.10 0.16 −0.05 ...

Page 11

Request for your special attention and precautions in using the technical information and (1) If any of the products or technical information described in this book exported or provided to non-residents, the laws and regulations of the ...