mt8982as Mitel, mt8982as Datasheet - Page 5

no-image

mt8982as

Manufacturer Part Number
mt8982as
Description
Iso-cmos St-bus Family Small Digital Switch Minidx
Manufacturer
Mitel
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT8982AS
Manufacturer:
ZARLINK
Quantity:
8 831
Part Number:
MT8982AS
Quantity:
2 802
Part Number:
MT8982AS
Manufacturer:
MITEL
Quantity:
20 000
into RxD by the rising edges of the next eight SCLK
cycles. If the operation is a read, eight data bits are
clocked from TxD by the falling edges of the next
eight SCLK cycles. The rising edge of CS tristates
TxD after the last transmitted bit.
Successive write microcycles can take place while
CS remains low, with each microcycle following the
sequence of a command/address byte followed by a
data byte. CS must go high after a read microcycle.
Note that a command/address byte must always
follow the high to low transition on CS.
When the MPS input is pulled high and the CS input
is pulled low, the microport is put into serial bus
mode. Pins RxD and SCLK become CSTi0 and
CSTi1, respectively, and are configured as 2048 kbit/
s serial streams with 32 channels each. The frame
and timeslot boundaries are determined by F0i and
C4. Each channel on CSTi0 and CSTi1 is stored in
the connect memory address corresponding to the
link and channel number. The Data Memory and the
Connect Memory cannot be read when the microport
is in serial bus mode.
2-6
0-1
0-4
Bit
Bit
7
7
6
5
Cmd0-Cmd1
SC0-SC4
Ch0-Ch4
Stream
Name
Name
ODE
STi
NA
Table 2. Connect Memory Connection Mode Data Byte
Stream. This is the most significant bit of the address for the memory location that
is to be accessed. It corresponds to one of the TDM serial streams (0-1).
Channel 0-4. These bits are the five least significant bits of the address for the
memory location that is to be accessed. The binary value of these bits correspond
to a TDM channel (0-31).
Command Select 0-1. These two bits define the four command operations for the
MT8982. The destination addressed by the command is defined in bits 2-7 of the
Command/Address byte.
Cmd0-Cmd1
Unused.
Output Drive Enable. When this bit is set, the addressed TDM channel is placed
in tristate. When low, the output is enabled.
Input Stream. This bit defines the input TDM stream from which the output data is
sourced (0-1).
Source Channel 0-4. The binary value of these bits defines the input channel from
which the output data is sourced (0-31).
0-0
0-1
1-0
1-1
Table 1. Command Address Byte
Read from Connect Memory.
Write to Connect Memory and set connection mode.
Read Data Memory.
Write to Connect Memory and set message mode.
Device Timing
During each TDM timeslot, eight read or write
operations occur internally in the MT8982. These are
shown in Figure 4. During the first two bit periods,
data received in the previous timeslot on the two
input TDM streams is loaded into the Data Memory.
Bit periods 2 and 6 are serial microport access
windows; data may be read from, or written to any
accessible memory location. During bit periods 3
and 5, data is read from the connect memory for the
next timeslot on links 0 and 1 respectively. The Data
Memory locations which are addressed by the
previous reads of the connect memory are accessed
during bit periods 4 and 7.
When the microport is in serial bus mode, bit periods
2 and 6 have a slightly different function. Data from
the
respectively is written to the corresponding connect
memory locations.
The transfer of information from the input TDM
streams to the output TDM streams results in a delay
through the MT8982. This delay is dependent only
on the combination of source and destination
Description
Description
previous
timeslot
ISO-CMOS
of
CSTi0
MT8982
and
CSTi1
2-35