... High accuracy internal cold junction compensation. Module provides +1500 V peak of galvanic transformer- based isolation with a common mode rejection (CMR) of 160 dB @ 50/60 Hz and a normal mode rejection (NMR 50/60 Hz. All 3B47 series modules are mix-and-match and Hot Swappable. APPLICATIONS Industrial signal conditioning Industrial signal isolation ...
Page 2
... GENERAL DESCRIPTION The 3B47 is a single-channel isolated thermocouple signal- conditioning module which interfaces, amplifies, isolates, protects, linearizes and filters analog input voltages from B-type thermocouple. The thermocouple input signal is internally linearized to provide an output voltage which is linear with temperature, High accuracy internal cold junction compensation and a predictable upscale open circuit indication provide a complete signal conditioning solution ...
Page 3
... Models Available Model Input Type 3B47-J-01 Type J 3B47-J-02 Type J 3B47-J-03 Type J 3B47-K-04 Type K 3B47-K-05 Type K 3B47-T-06 Type T 3B47-T-07 Type T 3B47-E-08 Type E 3B47-R-09 Type R 3B47-S-10 Type S 3B47-B-11 Type B 3B47-Custom Type The CJC sensor accuracy (refer to specification table) should be added to the module accuracy when computing system accuracy. ...
Page 4
... Temperature Range Rated Performance Storage Relative Humidity RFI Susceptibility 1 Current output is not available with model 3B47. 2 Includes the combined effects of repeatability, hysteresis, and nonlinearity wide range of zero suppression and span adjustment is available to enable field calibration. 4 When used with the CJC temperature sensor provided on the 3B Series backplane. Specifications subject to change without notice. ...
Page 5
... PIN CONFIGURATIONS AND FUNCTIONAL DESCRIPTIONS Figure 3 3B47 Input Field Connections Table 1. Pin Function Descriptions— Pin No. Description 1 N N/C ESD CAUTION ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although this product features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges ...
Page 6
... OUTLINE DIMENSIONS Figure 5. Outline Dimensions Rev Page 3B47 ...
Page 7
... NOTES Rev Page 3B47 ...
Page 8
... NOTES © 2004 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective companies. D05162-0-9/04(0) Rev Page 3B47 ...