bspm1690wer Cooper Bussmann, Inc., bspm1690wer Datasheet

no-image

bspm1690wer

Manufacturer Part Number
bspm1690wer
Description
Manufacturer
Cooper Bussmann, Inc.
Datasheet
Surge Protection Made Simple™ for Wind Power Applications
IEC Class II Surge Arresters for 75-1000 Volt, TN & TT Systems
Description
The Cooper Bussmann
pole, modular surge arresters feature local, easy ID™ visual indication and
optional remote contact signaling. The unique module locking system on the
75 to 690 volt arresters fixes the protection module to the base part. Modules
can be easily replaced without tools by simply depressing the release buttons.
Integrated mechanical coding between the base and protection module
ensures against installing an incorrect replacement module.
TN System Arresters (also 1-Phase TT systems)
The features of these single-pole devices are for use as a single device or in
combination with other devices.
TT System Arrester
Provides a current arresting means between neutral conductor and protective
conductor in TT systems, this device helps ensure fulfilling the requirements
for protection of personnel and equipment in “3+1” and “1+1” circuits.
Remote Signaling Contact
The three-pole terminal remote signaling contact versions have a floating
changeover contact for use as a break or make contact, according to circuit
concept.
Module Circuit Diagrams -
0211
www.cooperbussmann.com/surge
BU-SB11088
BSPM1400WE(R)
BSPM1690WE(R)
BSPM175WE(R)
MOV
®
IEC Class II 75, 230, 400, 690 and 1000 volt, one-
Shown with optional remote contact signaling
Thermal Disconnector
BSPG1230WE(R)
Gas Discharge Tube (single)
BSPM11000WE(R)
Page 1 of 2
Visual Status Indication
Dimensions - mm
Data Sheet 2092
BSPM175WE(R)
BSPG1230WE(R)
BSPM1400WE(R)
BSPM1690WE(R)
BSPM11000WE(R)
Contact Available
Remote Signal
1000V Arrester
75 to 690V
Arresters
contact signaling
optional remote
Shown with

Related parts for bspm1690wer

bspm1690wer Summary of contents

Page 1

Surge Protection Made Simple™ for Wind Power Applications IEC Class II Surge Arresters for 75-1000 Volt, TN & TT Systems Description The Cooper Bussmann ® IEC Class II 75, 230, 400, 690 and 1000 volt, one- pole, modular surge arresters ...

Page 2

... DIN rail per EN 60715 Thermoplastic, UL 94V0 Remote Contact Signaling 250V/0.1A; 125V/0.2A; 75V/0.5A 60/75°C Max. 1.5mm Order from Catalog Numbers Above Page 400V/1 690V/1 440V 600V BSPM1400WE BSPM1690WE BSPM11000WE BSPM1400WER BSPM1690WER BSPM11000WER BPM440WE BPM750WE 585 600V - - 750V 20kA 15kA 40kA 25kA - - ...

Related keywords