mpm-15s-48 MicroPower Direct, LLC, mpm-15s-48 Datasheet - Page 2

no-image

mpm-15s-48

Manufacturer Part Number
mpm-15s-48
Description
Compact, 15w Pc Mount Single, Dual & Triple Out Ac/dc Power Supplies
Manufacturer
MicroPower Direct, LLC
Datasheet
Model Selection Guide
Notes:
1. Leakage current specifi ed for dual and triple output models only.
2.
3. The MPM-15 series is specifi ed for operation over the wide operating temperature range of -20°C to +55°C
4. Single output models are approved to EN60950. Approval for other models is pending.
5. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-15
Mechanical Dimensions
Notes:
MPM-15S-03
MPM-15S-05
MPM-15S-12
MPM-15S-15
MPM-15S-24
MPM-15S-48
MPM-15D-05
MPM-15D-12
MPM-15D-15
MPM-15T-0505
MPM-15T-0512
MPM-15T-0515
MPM-15T-0524
All dimensions are typical in inches (mm)
Tolerance x.xx =
Load regulation is measured for an output change of 10% to 90% at nominal input line. For multiple output
models, the loads are balanced.
without derating. For operation over +55°C, derate the power linearly by 3.75%/°C from +55°C to +70°C.
series, a 2A/250 VAC slow blow should be used.
Number
Model
±
0.01 (
115
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
±
Current
0.25)
VAC
Pin Connections
Input
292 Page Street Ste D Stoughton, MA 02072
Pin
MicroPower Direct
We Power Your Success - For Less!
1
2
3
4
5
6
7
8
230
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
(A)
AC-Neutral AC-Neutral AC-Neutral
VAC
AC-Line
No Pin
No Pin
No Pin
No Pin
Single
+Vo 1
-Vo 1
Voltage
(VDC)
+12.0
+15.0
+5.0
12.0
15.0
24.0
48.0
3.3
5.0
5.0
5.0
5.0
5.0
AC-Ground AC-Ground
Common
AC-Line
No Pin
No Pin
+Vo 1
-Vo 2
Rated
Dual
3.000
2.800
1.250
1.000
0.625
0.320
+1.50
+0.65
+0.50
Output 1
2.60
2.00
1.80
2.00
Current
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±2.0%
±2.0%
±2.0%
±3.0%
±3.0%
±3.0%
±3.0%
Load
Reg.
(Vout 1)
(A)
Common
AC-Line
Triple
+Vo 1
+Vo 2
-Vo 1
-Vo 2
Protection
Over Volt.
(VDC)
20.0
20.0
30.0
30.0
20.0
20.0
6.5
6.5
6.5
6.5
6.5
6.5
6.5
TEL: (781) 344-8226
Voltage
(VDC)
+12.0 +0.20 ±5.0%
+15.0 +0.20 ±5.0%
+24.0 +0.10 ±5.0%
-12.0
-15.0
+5.0 +0.20 ±5.0%
-5.0
www.micropowerdirect.com
Typical Connection
Typical Component Values
Notes:
1. C1, C3 and C5 are high frequency, low resistance electrolytic capacitors.
Refer to the suppliers specifi cations for capacitance/current ratings.
Vout
12.0
15.0
24.0
48.0
Rated Load
Output 2
3.3
5.0
-1.50 ±2.0%
-0.65 ±2.0%
-0.50 ±2.0%
Current
Reg.
330 ~ 1,000 µF/16V
330 ~ 1,000 µF/16V
FAX: (781) 344-8481
(Vout 2)
(A)
C1, C3, C5
220 µF/25V
220 µF/25V
120 µF/35V
68 µF/63V
Protection
Over Volt.
2. Voltage derating on all capacitors should be
3. C2, C4 and C6 eliminate high frequency noise.
4. The TVS is recommended to protect load
(VDC)
80% or higher.
circuitry in the event of a module failure.
20.0
20.0
6.5
Voltage
(VDC)
C2, C4, C6
0.1 µF/50V
-12.0 -0.20 ±5.0%
-15.0 -0.20 ±5.0%
-24.0 -0.10 ±5.0%
Ceramic
-5.0 -0.20 ±5.0%
Output 3
E-Mail: sales@micropowerdirect.com
Rated Load
Current
(Vout 3)
Slow Blow
250 VAC
Fuse
2A/
Reg.
(A)
Effi ciency
P6KE6.8A
P6KE6.8A
P6KE16A
P6KE20A
P6KE33A
P6KE62A
(%, Typ)
TVS
80
80
80
80
80
80
80
80
80
80
80
80
80

Related parts for mpm-15s-48