s82y-h10f ETC-unknow, s82y-h10f Datasheet - Page 10

no-image

s82y-h10f

Manufacturer Part Number
s82y-h10f
Description
Switching Power Supply
Manufacturer
ETC-unknow
Datasheet
Operation
J REMOTE SENSING FUNCTION
The remote sensing function makes it possible to compensate for
voltage drops caused by load lines. To use this function, remove
the short bar from the remote sensing terminals and wire the
Power Supply and load as shown in the following illustration. The
remote sensing terminals are short-circuited with the short bar
before shipping.
Note:
J BLOCK DIAGRAMS
S82H-31jj
S82H-33jj
S82H-35jj
100-W and 150-W Models
* Fuse Capacity
Level
L (0.8 V max.)
H (2 V min.)
10
Remote sensing connection
15 W: 2 A
30 W: 2.5 A
50 W: 3 A
(2-conductor shielded wire)
Load connection lines
120/240 V selector
No output will be produced if the terminals are left
unconnected. Be sure to firmly tighten the terminal screws.
Switching Power Supply
INPUT
L
N
ACG
FG
Fuse *
Output voltage
ON
OFF
Noise
filter
Remove
short bars.
S82H
Inrush current
protection circuit
Control circuit
Overload
detector
Smoothing
circuit
Photocoupler
Rectifier
Rectifier
+V
–V
DC OUT