Safety Isolation System ElectroGuard Overview The ElectroGuard Safety Isolation System is used in place of a disconnect switch for Lockout and Tagout (LOTO). It uses power contactors and Remote Lockout Stations to accomplish LOTO. Isolating the electrical energy usually involves ...
Page 2
... Lockout Stations to be used (see page 12-16 for details). • Pneumatic Isolation Module to isolate pneumatic energy (see page 12-15 for details). • Status communication to a remote PLC (see page 12-17 for details). • Fusible disconnect switch (Bulletin 2032) or thermal-magnetic circuit breaker (Bulletin 2033) to provide branch circuit protection. To Motor Controllers ...
Page 3
... Input Power Feed Catalogue Number Code The Catalogue Number as listed is incomplete. Select an Input Power Feed Code from the table below. Example: Catalogue Number 2032*-A0630J -30L becomes Catalogue Number 2032T-A0630J -30L for a “Top Feed” input power requirement. Input Power Feed ...
Page 4
... Bussing Designation The Catalogue Number as listed is incomplete. Select a Bussing Designation Code from the table below. ! 0085J -26J becomes Cat. No. 2032-M0085J -26J for “600A Line Side Incoming Bus and Outgoing Power Cables” bussing Example: Cat. No. 2032- designation. Type of Bussing 600A Line Side Incoming Bus and Outgoing Power Cables ...
Page 5
Combination Systems with Thermal-magnetic Circuit Breaker/Optional Features Product Selection for Outside of North America (see page 12-19 for Ordering Instructions) ! Bussing Designation The Catalogue Number as listed is incomplete. Select a Bussing Designation Code from the table below. ! ...
Page 6
... Bulletin 2032 or 2033 Systems only) e.g. Catalogue Number 2032T -A0630JB-30L becomes Catalogue Number 2032T -A0630JB-30L-2EUT to indicate a 630A Safety Isolation System that includes 2 internally installed 10 port Expansion Modules without the time delay feature. Open Type Expansion Module for Field Addition ...
Page 7
Status Communication to a remote PLC (Should be ordered with Safety Isolation System) This option provides Remote I/O via “Flex” modules. Communication can be via: • The DeviceNet communication platform, or • The Remote I/O communication platform. Note: The status ...
Page 8
Safety Isolation System ElectroGuard Typical Wiring Diagram/Wire Length Considerations Typical Wiring Diagram Safety Isolation System GC with Optional Fusible Disconnecting Means 1IC 2IC Designates Remote field Lockout connection Station(s) points Wire Length Considerations ATTENTION: ...
Page 9
The total wire length for the 5 RLS to be wired to the Control Module will be: 100ft + 400ft + 200ft + 600ft + 1,000ft = 2,300ft Per the table entitled Total Wire Length for Remote Lockout Stations on ...