ilx554 Sony Electronics, ilx554 Datasheet
ilx554
Available stocks
Related parts for ilx554
ilx554 Summary of contents
Page 1
... CCD Linear Sensor (B/W) for Single 5V Power Supply Bar-code Reader For the availability of this product, please contact the sales office. Description The ILX554A is a rectangular reduction type CCD linear image sensor designed for bar code POS hand scanner and optical measuring equipment use. ...
Page 2
... ROG Symbol Pin No GND Max. Unit 5.5 V Max. Unit 0.5 V Min. Typ. Max. — 10 — — 10 — – 2 – ILX554A Description GND 5V power supply NC NC Unit pF pF ...
Page 3
... VDD 98.0 92 TTE 250 Z — O 2.85 V — OS The maximum output of all the valid pixels is set to V 100 [%] the minimum output 500mV. OUT – 3 – ILX554A Max. Unit Remarks 300 V/(lx · s) Note 1 — V/(lx · s) Note 2 10.0 % Note 3 — V — 6.0 mV Note 4 12.0 mV Note 4 — ...
Page 4
Clock Timing Diagram (without S/H mode) 5 ROG 0 5 CLK 0 V OUT Dummy signal (32 pixels) Without S/H mode (4 pin Note) 2090 or more clock pulse are required. Optical black (18 pixels) Effective picture elements signal Dummy ...
Page 5
Clock Timing Diagram (with S/H mode) 5 ROG 0 5 CLK 0 V OUT Dummy signal (33 pixels) With S/H mode (4 pin Note) 2090 or more clock pulse are required. Optical black (18 pixels) Effective picture elements signal (2048 ...
Page 6
... ROG pulse period Symbol Min — Symbol Min 1000 1000 – 6 – ILX554A Typ. Max. Unit 10 100 Typ. Max. Unit 3000 — ns 3000 — — ns 5000 — ns ...
Page 7
... Note 1) fck = 1MHz, CLK pulse duty = 50%, CLK pulse rise/fall time = 10ns Note 2) Output waveform when internal S use. Note 3) indicates the correspondence of clock pulse and data period. (Note 3) t11 t12 Symbol Min. Typ 100 210 150 – 7 – ILX554A Max. Unit 250 ns 410 ns 250 ns ...
Page 8
... Example of Representative Characteristics 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 400 Dark voltage rate vs. Ambient temperature (Typ.) 10 0.1 Spectral sensitivity (Typ.) (Ta = 25˚C) 500 600 700 800 Wavelength [nm – Ambient temperature [˚C] – 8 – ILX554A 900 1000 60 ...
Page 9
... Output voltage rate vs. Integration time (Typ 0 Integration time [ms] Offset level vs. V (Typ.) DD 3.2 3.1 3.0 2.9 2.8 2.7 2.6 2.5 2.4 4.50 4.75 5.00 5.25 V [V] DD Current consumption rate vs. Clock frequency (Typ.) 2.0 1.5 1.0 0.5 0 100 0 0.5 1.0 Clock frequency [MHz] Offset level vs. Ambient temperature (Typ.) 3.2 3.1 3.0 2.9 2.8 2.7 2.6 2.5 2.4 5. Ambient temperature [˚C] – 9 – ILX554A 1.5 2 ...
Page 10
... Note 22µ/10V 100 CLK – 10 – ILX554A 100 ROG ...
Page 11
... For repairs and remount, cool sufficiently dismount image sensors, do not use a solder suction equipment. When using an electric desoldering tool, ground the controller. For the control system, use a zero cross type. 29N 29N (2) (3) – 11 – ILX554A 0.9Nm (4) ...
Page 12
... Exposure to high temperature or humidity will affect the characteristics. Accordingly avoid storage or usage in such conditions. 6) CCD image sensors are precise optical equipment that should not be subject to mechanical shocks. 7) Normal output signal is not obtained immediately after device switch on. Use the output signal added 22500 pulses or above to CLK clock pulse. – 12 – ILX554A ...
Page 13
Package Outline Unit: mm 41.6 ± 0.5 6.46 ± 0.5 28.672 (14µm X 2048Pixels No.1 Pixel H 1 2.54 PACKAGE STRUCTURE Cer-DIP PACKAGE MATERIAL LEAD TREATMENT TIN PLATING 42 ALLOY LEAD MATERIAL PACKAGE MASS 5.20g DRAWING NUMBER LS-A20(E) ...